www.charltonandjenrick.co.uk
13
LT7272 (ISS 1)
SECTION SIX Regulations and Warnings (installation instructions)
THIS APPLIANCE MUST ONLY BE INSTALLED IN GB OR IRELAND.
Only to be used in sufficiently ventilated room. Read instructions carefully before installation and use. The
appliance must be installed by a competent person, i.e.. Gas Safe Registered Installer in accordance with the
current Gas Safety (Installation and Use) Regulations 1998 (as amended). Failure to do so could lead to
prosecution.
This PARAGON P3 is for use ONLY with the GAS STATED ON THE DATA BADGE this may be G20 for Natural Gas
CHECK YOU HAVE THE CORRECT APPLIANCE FOR THE GAS YOU ARE USING.
It can be used in conjunction with the following chimneys: -
A sound conventional brick or stone chimney, or lined with appropriate liner.
A metal flue and box conforming to BS 715, further details are covered in later text.
A non-combustible hearth must be provided to comply with the building regulations or a suitable proprietary
fire surround with a 100 degrees C rating.
During initial firing an odour may be evident. This is the binder used during the manufacture of the fibre
components and there are no harmful effects produced.
The following are relevant Codes of Practice and British Standards: -
BS 5871
BS 8303
BS 5440 part 1
BS 1251
BS 6891
BS 6461 parts 1 & 2
BS 715
BS 1289 part 1& 2
Note:- This appliance must be installed to current versions of the above standards and include any relevant
amendments.
The Building Regulations issued by the Department of the Environment
The Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development Office.
SECTION SEVEN Siting the Appliance (installation instructions)
The fire can be installed in the following flues and locations: -
CLASS ONE
A conventional brick or stone chimney as used for a solid fuel appliance with a typical effective cross-sectional
dimension of 225 x 225 mm (9 x 9 ins) or a lined flue with a minimum diameter of 125 mm (5 ins).This includes pre-
cast flue systems. Please note a minimum of 620mm high within the builders opening is required when installing
this appliance. (This is due to the fitting of the flue adaptor)
Note: The restrictor plate (fitted to the fire) may be left in place with flues of 175mm (7") or greater. This being
subject to satisfactory products clearance.
Fireplace opening must be 560 mm - 580 mm high by 415 mm – 445 mm wide.
The opening depth must be a minimum of 320 mm to allow sufficient volume for debris collection.
To obtain this depth it may be necessary to remove the chairbrick.
Any permanent flue restriction or variable dampers are to be removed or locked fully open. The chimney should be
swept prior to installation if not new.
Содержание Paragon P3
Страница 8: ...8 LT7272 ISS 1 ...
Страница 9: ...www charltonandjenrick co uk 9 LT7272 ISS 1 ...
Страница 10: ...10 LT7272 ISS 1 ...
Страница 19: ...www charltonandjenrick co uk 19 LT7272 ISS 1 Insert the flue adaptor within the roof of the firebox as shown ...
Страница 24: ...24 LT7272 ISS 1 ...
Страница 25: ...www charltonandjenrick co uk 25 LT7272 ISS 1 Register your appliance online today to active your warranty ...