![Charlton & Jenrick Paragon P3 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/charlton-and-jenrick/paragon-p3/paragon-p3_owners-manual_2591707012.webp)
12
LT7272 (ISS 1)
Fret
A Fret must be used with this appliance, and must conform to the following: -
It must be made from non-combustible
material.
Its general construction should enable it to
stand firmly across the full width of the
burner.
The design of the fire front (fret) must have
a removable ashtray cover (lower section).
The ash tray cover must have cut-outs and
or holes which provide ventilation to the
underside of the burner.
The effective area of ventilation through the
ash tray cover must be greater than
1365mm2 (2.12 sq. ins.)
SECTION FIVE Specification (installation instructions)
NATURAL GAS
Category of Appliance:
B
AS
Category
I
2H
Gas type:
G20
Gas Pressure:
20 mbar
Gas input high:
7.7 kW Gross
Gas input low:
4.0 kW Gross
Injector Main:
Size 580
Oxy-pilot
2550 NG
Data Label Location:
On top flange of firebox
Gas Connection:
8 mm OD Tube
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2009 + A1:2013 and the result is 63.7 %. The gross calorific
value of the fuel has been used for this efficiency calculation. GASTEC have certified the test data from which it has been calculated. The
efficiency value may be used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings.
Содержание Paragon P3
Страница 8: ...8 LT7272 ISS 1 ...
Страница 9: ...www charltonandjenrick co uk 9 LT7272 ISS 1 ...
Страница 10: ...10 LT7272 ISS 1 ...
Страница 19: ...www charltonandjenrick co uk 19 LT7272 ISS 1 Insert the flue adaptor within the roof of the firebox as shown ...
Страница 24: ...24 LT7272 ISS 1 ...
Страница 25: ...www charltonandjenrick co uk 25 LT7272 ISS 1 Register your appliance online today to active your warranty ...