www.charltonandjenrick.co.uk
23
LT8229 (ISS 3)
Rear Exit: Using optional Edge Gas Stove rear vent Kit (Part Number 8112 )
Precast Flue (Please note the Spigot restrictor plate must be removed)
The appliance can be installed to a precast concrete or clay flue block system conforming to BS1289 or BS EN 1806.
The appliance is suitable for installation conforming to older versions of BS1289. The cross
–
sectional area must not
be less than 13,000mm2. The chimney vertical height must not be less than 3m and be correctly terminated.
To achieve the rear exit option, the appliance gather hood will need to be removed. The outlet spigot from with the
rear vent kit will need to be attached to the firebox assembly and engaged within the closure plate.
Содержание Paragon Edge
Страница 11: ...www charltonandjenrick co uk 11 LT8229 ISS 3 ...
Страница 12: ...12 LT8229 ISS 3 ...
Страница 13: ...www charltonandjenrick co uk 13 LT8229 ISS 3 ...
Страница 14: ...14 LT8229 ISS 3 ...
Страница 15: ...www charltonandjenrick co uk 15 LT8229 ISS 3 ...
Страница 20: ...20 LT8229 ISS 3 ...
Страница 24: ...24 LT8229 ISS 3 ...
Страница 27: ...www charltonandjenrick co uk 27 LT8229 ISS 3 12 ...