8
LT 6935 (ISS 4)
e.
The appliance can be switched off without using the hand set by removing the appliance batteries
located below the air grill cover. When the batteries are removed there will be a delay (up
3minutes) after which, double bleeps may be heard and shortly after the appliance will
extinguish. Ensure that the battery is reconnected once the fire has been extinguished. The
appliance cannot be operated without the use of the handset.
Room Thermostat mode
The remote handset checks the room temperature at a fixed time intervals. Depending on the
difference between set room temperature and the actual room temperature the remote proceeds
to modulate in one level steps. Once the room temperature is reached it moves to standby position
pilot only.
The icon “PILOT” will appear on the LCD display. As soon as the actual room temperature falls below
the SET room temperature, the system will move from standby to the high flame level. From this
point it will proceed again the modulation process.
Note: Due to the temperature checks at timed intervals, the display temperature on the handset may
exceed the room setting temperature before the appliance defaults to the pilot setting
.
TO REPLACE BATTERY IN HAND SET (3 AAA TYPE BATTERIES)
Remove the cover from the rear of the handset and fit replacement batteries.
Clock Regulation
As soon as the batteries are fitted the timer digits will blink. Using the
arrow
key increase or decrease the hour, minutes and week`s value. By pressing the
O
will set and shift setting until complete.
Changing Clock Setting During Operation
To amend timer setting press both the
and
O
keys simultaneously for three seconds, the
written clock will appear. To change the clock settings, repeat the above described operation.
Change From Celsius to Fahrenheit
With remote OFF, keeping pressed
key at least for 5 seconds, the temperature unit changes from
Celsius to Fahrenheit degrees and vice versa.
Содержание INFINITY 480 BF
Страница 25: ...www charltonandjenrick co uk 25 LT 6935 Iss 4 FIG 5 FIG 4 FIG 5 ...
Страница 34: ...34 LT 6935 ISS 4 SECTION FIFTEEN Wiring Diagram maintenance instructions Attach to the valve ...
Страница 36: ...36 LT 6935 ISS 4 ...
Страница 37: ...www charltonandjenrick co uk 37 LT 6935 Iss 4 ...
Страница 38: ...38 LT 6935 ISS 4 ...