www.charltonandjenjick.co.uk
7
LT6935 (ISS 4)
SECTION TWO: Introduction(Users Instructions)
The INFINITY 480 BF is an inset room sealed decorative fuel-effect gas appliance designed for use in
locations that do not have a conventional chimney. The appliance must be installed against an outside
wall because the air to support combustion is taken from the outside and the products of combustion are
expelled to the outside.
The appliance incorporates a safety device in the form of a FLAME SUPERVISION DEVICE, which
constantly monitors the flame and will cause the gas to be switched off if the flames are extinguished
for any reason. THIS DEVICE MUST NOT BE OVERRIDDEN. If this situation occurs on a regular basis
have the appliance checked by a qualified engineer. The problem may be due to a blocked or restricted
flue.
Before removing the, trim, glass shapes for cleaning the fire should be turned off, and left to cool down.
NOTE: In use some discoloration of the components will take place in the combustion box, this is normal,
but can be kept to a minimum if the shapes are placed correctly (i.e. after cleaning). See Section 4.
As with all heating appliances certain areas (Working Surfaces) become very hot when the appliance is
in use.
SECTION THREE: Operation(Users Instructions)
To light the appliance using the remote hand set:
a.
Point the remote control hand set in the direction of
the appliance and press the
button. Continue to
hold the button for approximately 2 seconds and
release handset screen will turn orange. When
released a bleep should be and heard the appliance
will automatically go through the ignition sequence
and the pilot should ignite. Once the pilot is alight the
appliance will automatically go to the high setting
(approximately 20-25sec).
b.
If the ignitor stops sparking and the pilot fails to light
press the
button for at least 2 seconds and
release,
again a bleep should be heard. Then repeat the lighting procedure.(need to wait 3 mins)
c.
With the appliance lit, by pressing
key the operational mode is switched from manual to room
thermostat setting and vice versa. When room thermostat mode is active, the display shows the set
temperature value and the “AUTO” icon will appear on the LCD display. By using the
arrow key the
desired room temperature can be set. When manual mode is active, the display shows the “MAN” icon
plus the flame icon and a five level bar icon setting. By pressing the
arrow key, the flame picture can
be adjusted at five stages between high and low flame. If level 5 is currently active, the icon max
below the flame icon will appear.
d.
To switch off the appliance press the
button for at least 2 seconds and on releasing the button the
appliance will bleep and then shut off. For pilot setting press the
for 1 second and release. The pilot
symbol will appear on the LCD display. Pressing the
button will bring the fire back onto main flame.
Содержание INFINITY 480 BF
Страница 25: ...www charltonandjenrick co uk 25 LT 6935 Iss 4 FIG 5 FIG 4 FIG 5 ...
Страница 34: ...34 LT 6935 ISS 4 SECTION FIFTEEN Wiring Diagram maintenance instructions Attach to the valve ...
Страница 36: ...36 LT 6935 ISS 4 ...
Страница 37: ...www charltonandjenrick co uk 37 LT 6935 Iss 4 ...
Страница 38: ...38 LT 6935 ISS 4 ...