FUEL SYSTEM
The internal fuel system on your Chaparral boat meets all current
Federal requirements.
Fuel lines, filters, and all fuel system components should be
checked at the start of each season and periodically thereafter, par-
ticularly after any work has been done aboard the boat which might
have affected any part of the system. Be certain that all are in
proper condition and that the entire system is fuel tight.
The fuel tank is located forward of the engine compartment under
the cockpit floor. The fuel tank fill pipe is located on the outside
deck. Some models have a dual fuel system, providing convenience
and flexibility of refilling your fuel tank from either side of the boat.
The fuel tank vent allows air to escape as the tank is being filled and
helps equalize tank pressure as temperatures change. The tank
has an anti-siphon valve which keeps fuel from leaking into the boat
in case of fuel line breaks.
Periodically, check the condition of the fuel tank components. Fuel
tank fittings are accessible through the inspection plate of the cock-
pit floor.
Note: The fuel fill cap has a built in tank ventilation feature. If
you should need to replace the cap, see your Chaparral dealer
for the exact cap to ensure proper fuel system operation.
Fuel Recommendations:
The quality of the fuel is very important for satisfactory engine per-
formance and long engine life. Fuel should be clean and free of
contamination. Your fuel tanks should be kept full of fuel whenever
possible. This will reduce the amount of water condensation and
reduce the possibility of contamination
FRESH WATER SYSTEM
The fresh water system provides water from an onboard storage
tank. Figure 3.3 shows a typical system and its components. A hot
water heater can provide hot water to the fresh water system. Before
using any fresh water system component, the water pump breaker
switch on the DC electrical panel must be switched on. When using
the shower in the head compartment, be sure to switch on the sump
pump switch (if so equipped) on the DC electrical panel, to activate
3-10
WARNING: Explosion Hazard!
Waste in the holding tank can
form methane, an explosive gas. Keep vent open and clear of
obstructions. Keep fire and flame away when maintaining
sanitation system.
VACUUM
TOILET
VACUUM
GENERATOR
THRU-HULL FITTING
T SERIES
DISCHARGE
PUMP
DECK DISCHARGE
VENT
FILTER
TANKWATCH
HOLDING TANK
VENT
FITTING
1) VENT FILTER STANDARD ON SIGNATURE
MODELS 270 AND LARGER.
2) VACUUM GENERATOR IS INTEGRATED
WITH HOLIDNG TANK ON MOST CHAPARRAL
MODELS.
SEE NOTE 2
SEE NOTE 1
12VDC
LEVEL MONITOR SYSTEM
R
EMPTY
MID
FULL
Figure 3.4 VacuFlush
®
System
VACUUM
TOILET
THRU-HULL FITTING
T SERIES
DISCHARGE
PUMP
DECK DISCHARGE
VENT
FITTING
VACUUM
HOLDING TANK
Содержание 2012 Signature
Страница 16: ...1 7...
Страница 17: ......
Страница 125: ......
Страница 133: ......
Страница 140: ...WIRING SCHEMATICS 12 12 1 Signature 370 Bilge D C Distribution Harness...
Страница 141: ...12 2 Signature 370 Helm Circuit Breaker Panel...
Страница 142: ...12 3 Signature 350 Bilge D C Distribution Harness...
Страница 143: ...12 4 Signature 350 Helm Circuit Breaker Panel...
Страница 144: ...12 5 Signature 330 Fwd D C Distribution Harness...
Страница 145: ...12 6 Signature 330 Helm Circuit Breaker Panel...
Страница 146: ...12 7 Signature 310 Aft D C Bilge Distribution Harness...
Страница 147: ...12 8 Signature 310 Helm Circuit Breaker Panel...
Страница 148: ...12 9 Signature 290 Bilge D C Distribution Harness...
Страница 149: ...12 10 Signature 290 Helm Circuit Breaker Panel...
Страница 150: ...12 11 Signature 270 Bilge D C Distribution Harness...
Страница 151: ...12 12 Signature 270 Helm Circuit Breaker Panel...