background image

18

IR Considerations

Avoid locating any of the cables, sensors, or keypads near any potential sources of ElectroMagnetic Interference
(EMI) such as light dimmers, speed controls for ceiling fans, electrical ballasts, television sets, large motors,
heaters, or air conditioners.  

Each room must be home run (wired directly) to its assigned sensor input.  Recommended cables are "data grade"
cables made of twenty-two gauge or larger conductors surrounded by a foil shield and a bare ground wire.
Twenty-two to sixteen gauge shielded cable with a drain wire will accommodate 150 to 600 foot runs to each
sensor.  CAT 5 is acceptable.

Reception range depends on the device being controlled and the levels of IR or EMI present.

The remote should be held vertical and with no more than 45 degrees off axis for nominal reception angle.

Be aware that different types of equipment have different latencies.  Latency is an apparent delay between when
the command is issued and the unit responds.  Some equipment may appear to respond faster than others and this
is normal.

Keypads generally use one of two types of signal transmittal - either current driven or voltage driven, meaning
that the actual data is conveyed as either a current pulse or voltage pulse traveling down the wire.  Each method
has advantages and disadvantages, but to be compatible with as many different set-ups as possible, the A6600
comes with a set of 82-ohm resistors.  These should be inserted between INPUT and GROUND signal lines at the
Euro connector if the keypad you are using seems to be malfunctioning.  This will compensate for line variances
from method to method.

One keypad can be combined with one IR sensor within the same room.  Do not use more than one receiver in a
room.  If more than one receiver picks up the same signal, the A6600 may not respond. 

Connection

Most Infrared receivers use a 4-screw terminal block.  Follow the connections supplied with the instruction manu-
al of the unit.  Keypads with built in IR pass-thru usually have the IR receiver connected internally.  See KEYPAD
section for details.  If your unit only uses three wires, either connect the status and +12VDC wires together at the
keypad or leave the status wire disconnected at both ends of the cable. 

The IR/Keypad wiring is pulled down to the A6600 and connects to the supplied Euro connector detailed in the
KEYPAD section.  

NOTE:  Some installations may require use of the supplied 82-OHM resistor for reliable reception.  See section

above and "Understanding Keypads". 

Flashers/Emitters

The ARIA A6600 has seven IR emitter outputs located on the rear panel: Zone 1, Zone 2, Zone 3, Zone 4, Zone 5,
Zone 6 and Common.  The Zone 1-6 outputs provide IR signal output from their respective zones, while the
Common output provides IR signal output from all zones.  The Common output would most likely be used to con-
trol source equipment needed by every zone, such as CD players etc. The Zone 1-6 outputs are used to control
equipment that is proprietary to a particular zone.

Place the emitter/flasher over the receiver window on the equipment to be controlled, and insert the jack into the
Zone Output plug corresponding to the location where zone control is desired.

Содержание Aria A6600

Страница 1: ...Channel Vision A6600 Multi Room Home Theater Processor Channel Vision 234 Fisher Avenue Costa Mesa CA 92626 USA 800 840 0288 714 424 6500 714 424 6510 fax www channelvision com email sales channelvis...

Страница 2: ...rview Diagram 13 ARIA Remote 14 Keypads Understanding and Installation 15 Infrared Receivers and Emitters Understanding and Installation 17 Cascading Units Paging 19 Page Connection Diagram 20 Underst...

Страница 3: ...n sink laundry tub in a wet basement or near a swimming pool 6 Carts and Stands The unit should be used only with a cart or stand that is recommended by the manufacturer A unit and cart combination sh...

Страница 4: ...ail it back to Channel Vision 234 Fischer Avenue Costa Mesa CA 92626 Be sure to retain a copy and keep it in a safe place 2 Power WARNING BEFORE TURNING ON THE POWER FOR THE FIRST TIME READ THE FOLLOW...

Страница 5: ...el audio signal through only two front firing speakers but sounds like a six speaker system The A6600 offers the ultimate in multi room home theater performance by including audio loop through on all...

Страница 6: ...f audio may be connected more through optional expansion Independent Zone Selection every zone can individually receive or control any source Independent Volume Control every zone has independent volu...

Страница 7: ...e length as short as possible to keep signal integrity intact 2 Connect each ZONE AUDIO OUTPUT Left and Right to the appropriate channel or line input connector on the power amplifier Refer to the ins...

Страница 8: ...ower Amplifier up to 12 channels A A A A A A B B B B B B C C C C C C Diagram shows cabling used with Aria A Cat 5 Alpha P N 9504C B 16 4 speaker cable Alpha P N 5434 C RCA audio cables PI Manuf P N RC...

Страница 9: ...UDIO OUT AUDIO OUT AUDIO OUT AUDIO OUT AUDIO OUT DVD VCR 1 SAT SOURCE 1 CD PLAYER TUNER FRONT REAR CNTR POWER AMPLIFIER 12 CHANNEL ARIA ROOM 1 L R ROOM 2 L R ROOM 3 L R ROOM 4 L R ROOM 5 L R ROOM 6 L...

Страница 10: ...0 2 Select the desired zone 3 Select the desired source 4 Adjust the volume Power On Off Fig 2 1 Press the POWER button on the ARIA The power on indicator should change from RED to GREEN Zone Operatio...

Страница 11: ...Red The room is selected The room is on The room is off The room is muted Zone Select buttons activate zone 1 2 3 4 5 6 VOLUME SRS O DOWN UP MUTE O PARTY PROGRAM POWER ZONE SELECT 1 2 3 4 5 6 VOLUME S...

Страница 12: ...le from IR Remote only 1 On the remote press the BASS or MID or TREB UP DOWN buttons as needed until desired affect is achieved TruSurroundTM SRSTM Center or Space Control Available from IR Remote onl...

Страница 13: ...hange to solid green indicating that the ARIA has reverted back to System Status display At any time while in Zone status display light blinking the front panel may be used for operation or adjustment...

Страница 14: ...ng has been applied Another press of the button turns SRS to the zone off VOLUME SW16 SW17 The volume level of each zone can be adjusted up or down as the listener desires Pressing and holding the UP...

Страница 15: ...TUNER SOURCE 1 TruSurround 1 2 3 4 5 6 VOLUME SRS O DOWN UP ZONE ENABLE O PARTY PROGRAM POWER ZONE SELECT SW 8 SW 9 SW 10 SW 11 SW 12 SW 13 SW 14 Figure 1 a Figure 1 b SW 2 SW 3 SW 4 SW 5 SW 6 SW 7 S...

Страница 16: ...stage represents the directional properties of a concert or play and causes the listeners to perceive the performance as being live If these properties are weakly reproduced or missing the audio will...

Страница 17: ...s it pertains to this specific example Note that the keypad you choose MUST be programmable in order to learn the A6600 codes used for control Basic Keypad Function The basic function of the keypad is...

Страница 18: ...rt each wire into the Euro connector and tighten the retaining screw Pin 1 is INPUT Pin 2 is STATUS Pin 3 is GROUND Pin 4 is 12 VDC Once the wires are secure insert the connector into the appropriate...

Страница 19: ...sending unit modulated at some frequency to ensure better reception and then transmitted via infra red light over to the receiver The IR receiver detects the code and sends it through the cabling to t...

Страница 20: ...connector if the keypad you are using seems to be malfunctioning This will compensate for line variances from method to method One keypad can be combined with one IR sensor within the same room Do not...

Страница 21: ...d toward the upper right on the rear of each unit Make sure that switches 5 6 are down Additionally each Slave Unit should have switch 7 moved down also This triggers the chaining action Note that the...

Страница 22: ...E LFE INPUT STATUS GND 12V INPUT STATUS GND 12V INPUT STATUS GND 12V INPUT STATUS GND 12V INPUT STATUS GND 12V INPUT STATUS GND 12V 1 2 3 4 5 6 is a PROG Zone Keypad Inputs Page L R 1 2 3 4 5 6 DVD CD...

Страница 23: ...sisting of of 8 data bits each 1 stop bit using No parity DTE to DCE cable known as Straight Through and Sub D9 Female cable at the A6600 end The commands must be programmed as a packet before transmi...

Страница 24: ...ommand Protocol Definition for calculation method Let Length commandfields PACKETSENDING is byte array SIZE of command fields 2 headers 1 length byte 1cksum Main Let checksumvalue Firstpacketchecksum...

Страница 25: ...t 9600 baud no parity eight data bits and one stop bit 9600 8 N 1 Message Definition Each message will consist of a 2 byte header defined as 0x16 0x39 1 byte describing the number of command bytes con...

Страница 26: ...This number is the number that goes in the length byte You probably counted using the decimal system but computers only think in a world of ON OFF or what we call 1 s and 0 s To translate your value t...

Страница 27: ...46 2e 78 4e 110 6e 142 8e 174 ae 206 ce 238 ee 15 f 47 2f 79 4f 111 6f 143 8f 175 af 207 cf 239 ef 16 10 48 30 80 50 112 70 144 90 176 b0 208 d0 240 f0 17 11 49 31 81 51 113 71 145 91 177 b1 209 d1 24...

Страница 28: ...Select Source 4 0x11 Select Source 5 0x21 Select Source 6 0x22 Page Off 0x2E Page On 0x2F SRS TM Mode Toggle 0x07 Surround Mode Off 0x3A Surround Mode On 0x3B All Zones Sound Off 0x00 All Zones Sound...

Страница 29: ...amplifiers to implement it Few people were willing to make the investment and even those who did failed to perceive any real advantage The problem was that even though the cinemas had standardized on...

Страница 30: ...e bulk of the audio drawing you into the scene There is another set of speakers behind you reproducing both the ambient affects and other spatial information that wrap you into the center of the actio...

Страница 31: ...vantage of your equipment Turning off TruSurroundTM and SRSTM processing accom plishes this 7 If the source is in a multi channel format Dolby Digital AC 3 and there are only two speakers available do...

Страница 32: ...ect source 4 Power amplifier off Turn on Power amp 5 Source input cable loose faulty Repair or replace 6 Zone output cable loose faulty Repair or replace Distortion 1 Input level too high Adjust volum...

Страница 33: ...Program keypad 6 Excessive cable capacitance Attach 82 Ohm resistors to rear of A6600 If still inoperable obtain a shorter run of cable and connect keypad sensor to A6600 If operational consider a hig...

Страница 34: ...iscellaneous Line voltage 120 VAC 60 Hz 240 VAC 50 Hz European Version Power consumption 17 Watts Replacement fuses T2A 250V Dimensions 16 5 W x 10 5 D x 3 5 H Weight 7 lbs Warranty 2 year Remote Cont...

Страница 35: ...INSTALLER S NOTES 33...

Страница 36: ...se abuse or alteration of the equipment This warranty is extended only to the original purchaser and a purchase receipt invoice or other proof of original purchase date will be required before warrant...