CPG4000DHY-EU - 3500W WIRELESS REMOTE START OPEN FRAME INVERTER
TROUBLESHOOTING
29
EN
TROUBLESHOOTING
Problem
Cause
Solution
Engine will not start.
No fuel.
Add fuel.
Faulty spark plug.
Clean and adjust spark plug or replace.
Low oil level.
Fill crankcase to the proper level.
Place generator on a flat, level surface.
Spark plug wire loose.
Attach wire to spark plug.
Fuel valve is closed.
Open fuel valve.
START/STOP button in “OFF” mode.
Press START/STOP button to “STANDBY” mode
then again to “Start” or see manual start section.
Old fuel or water in fuel.
Drain fuel and replace with fresh fuel.
Flooded with fuel.
Let unit stand for 10 mins.
Engine starts but runs roughly.
Choke in the wrong position.
Move choke until it stops under RUN position or
push choke button if illuminated green.
Dirty air filter.
Clean or replace air filter.
Dirty fuel valve.
Clean the fuel valve.
Clogged spark arrestor.
Clean spark arrestor.
Engine will not start wirelessly.
Remote control battery is dead.
Replace remote control battery.
Generator battery is dead.
Recharge generator battery.
START/STOP button in “OFF” mode.
Press START/STOP button to “STANDBY” mode
then press “START” one time on remote.
Generator out of range of remote signal. Remote must be with 80 feet of generator.
Obstructions in between generator and
remote.
Clear line of site between generator and remote.
Engine will not start electrically.
Generator battery is dead.
Recharge generator battery.
START/STOP button in “OFF” mode.
Press START/STOP button to “STANDBY” mode
then again to “START”.
Engine shuts down during operation.
Out of fuel.
Fill fuel tank.
Low oil level.
Fill crankcase to the proper level. Place generator
on a flat, level surface.
Clogged spark arrestor.
Clean spark arrestor.
Generator cannot supply enough power
or overheating.
Generator is overloaded.
Review load and adjust. See “Connecting
Electrical Loads.”
Dirty air filter.
Clean or replace air filter.
Choke in wrong position.
Move choke until it stops under RUN position or
push choke button if illuminated green.
Engine is running but no AC output.
Poor cord connection.
Check all connections.
Circuit breaker is open.
Reset circuit breaker.
Faulty inverter module.
Call Technical Support Team.
Loose wiring.
Inspect and tighten wiring connections.
AC Overload: Button illuminated red
Reduce AC load and press Overload Reset Button
until illuminated green.
Other.
Contact the help line.