INSTALLATION
Do not operate unit if damaged during shipping, handling or use. Operating unit if damaged
may result in injury.
1.
Permanently installed compressors must be located in a clean, well ventilated dry room so compressor
receives adequate supply of fresh, clean, cool and dry air. It is recommended that a compressor, used
for painting, be located in a separate room from that area wherein body sanding and painting is done.
Abrasive particles or paint, found to have clogged the air intake filters and intake valves, shall
automatically void warranty.
2.
Compressors should never be located so close to a wall or other obstruction that flow of air through the
fan bladed flywheel, which cools the compressor, is impeded. Permanently mounted units should have
flywheel at least 12" from wall.
3. Place stationary compressor on firm level ground or flooring. Permanent installations require bolting to
floor. Bolt holes in tank or base feet are provided. Before bolting or lagging down, shim compressor
level. Avoid putting a stress on a tank foot by pulling it down to floor. This will only result in abnormal
vibration, and possible cracking of Air Receiver.
The vibro-isolator pads which came with the unit will need to be installed on the unit. Tanks bolted
directly to a concrete floor without padding will not be warranted against cracking. Champion vibro-
isolators must be used for extended warranty to apply to ASME air receivers.
Do not install isolating valves between compressor outlet and air receiver. This will cause
excessive pressure if valve is closed, and cause injury and equipment damage.
Always use an air pressure regulating device at the point of use. Failure to do so can result in
injury or equipment damage.
●
Do not install in an area where ambient temperature is below 32 degrees F or above
100 degrees F.
●
Do not install unit in an area where air is dirty and/or chemical laden.
●
Unit is not to be installed outdoors.
Содержание CADRSASP12
Страница 10: ...9 FIGURE 1 DUPLEX CONTROL PANEL WIRING DIAGRAM ...
Страница 12: ...11 INSTALLATION CONT D CIRCUIT BREAKERS 1 Factory wired No wiring required Figure 3 Circuit Breaker ...
Страница 13: ...12 INSTALLATION CONT D MOTOR CONTACTORS 1 Factory wired No wiring required FIGURE 4 MOTOR CONTACTORS ...
Страница 15: ...14 INSTALLATION CONT D LOW OIL LEVEL MONITOR 1 Factory wired No wiring required FIGURE 6 LOW OIL LEVEL MONITOR ...
Страница 16: ...15 INSTALLATION CONT D ELECTRIC TANK DRAIN 1 Factory wired No wiring required FIGURE 7 ELECTRIC TANK DRAIN ...
Страница 25: ...24 PARTS ILLUSTRATION MODEL CADRSASP12 307CAD810 A Ref Drawing ...
Страница 27: ...26 DUPLEX CONTROL PANEL MOUNTING 305CAD810 A Ref Drawing ...
Страница 39: ...38 UNIT HAZARD DECALS ...
Страница 40: ...39 PUMP HAZARD DECALS F ...