18
GUIDE TO MAINTENANCE
To obtain reliable and satisfactory service, this unit requires a consistent preventive maintenance schedule.
Maintenance schedule pages are included in the back of this manual to aid in keeping the proper records.
Before performing any maintenance function, switch main disconnect switch to "off" position to
assure no power is entering unit. "Lock Out" or "Tag Out" all sources of power. Be sure all air
pressure in unit is relieved. Failure to do this may result in injury or equipment damage
.
DAILY MAINTENANCE
1.
Check oil level of both compressor and engine if so equipped. Add quality lubricating oil as required.
See Section on "Oil Specifications".
2.
Drain moisture from tank by opening tank drain valve located in bottom of tank. Do not open drain
valve if tank pressure exceeds 25 PSIG.
3.
Check operation of electric tank drain by pushing manual test button located on drain.
4.
Turn off compressor at the end of each day's operation. Turn off power supply at wall switch.
WEEKLY MAINTENANCE
1.
Clean dust and foreign matter from cylinder head, motor, fan blade, air lines, intercooler and tank.
2.
Remove and clean intake air filters.
Do not exceed 15 PSIG nozzle pressure when cleaning element parts with compressed air. Do not
direct compressed air against human skin. Serious injury could result. Never wash elements in fuel
oil, gasoline or flammable solvent.
3.
Check V-belts for tightness
.
The V-belts must be tight enough to transmit the necessary power to the
compressor. Adjust the V-belts as follows:
a. Remove bolts and guard to access compressor drive.
b. Loosen mounting hardware which secures motor to base. Slide motor within slots of baseplate to
desired position.
c. Apply pressure with finger to one belt at midpoint span. Tension is correct if top of belt aligns with
bottom of adjacent belt. Make further adjustments if necessary.
d. Check the alignment of pulleys. Adjust if necessary.
e. Tighten mounting hardware to secure motor on base.
f.
Re-install guard and secure with bolts.
Never operate unit without belt guard in place. Removal will expose rotating parts which can cause
injury or equipment damage.
Содержание CADRSASP12
Страница 10: ...9 FIGURE 1 DUPLEX CONTROL PANEL WIRING DIAGRAM ...
Страница 12: ...11 INSTALLATION CONT D CIRCUIT BREAKERS 1 Factory wired No wiring required Figure 3 Circuit Breaker ...
Страница 13: ...12 INSTALLATION CONT D MOTOR CONTACTORS 1 Factory wired No wiring required FIGURE 4 MOTOR CONTACTORS ...
Страница 15: ...14 INSTALLATION CONT D LOW OIL LEVEL MONITOR 1 Factory wired No wiring required FIGURE 6 LOW OIL LEVEL MONITOR ...
Страница 16: ...15 INSTALLATION CONT D ELECTRIC TANK DRAIN 1 Factory wired No wiring required FIGURE 7 ELECTRIC TANK DRAIN ...
Страница 25: ...24 PARTS ILLUSTRATION MODEL CADRSASP12 307CAD810 A Ref Drawing ...
Страница 27: ...26 DUPLEX CONTROL PANEL MOUNTING 305CAD810 A Ref Drawing ...
Страница 39: ...38 UNIT HAZARD DECALS ...
Страница 40: ...39 PUMP HAZARD DECALS F ...