6
TWO STAGE AIR COMPRESSOR - R15B PUMP
DIMENSIONS
ITEM
R15B
A
B
C
D
E
F
I
J
K
L
M
N
O
P
Q
R
Base-Width
Bolt Down-Width
Bolt Down to Edge
Base to Crank Ctr
Overall Width
Overall Height
Bolt Down Hole Dia.
Base-Depth
Bolt Down Depth
Bolt Down to Edge
Bolt Hole to Wheel (Max.)
Flywheel Width
Crank Diameter
Flywheel Diameter
Flywheel Grooves
Overall Depth
10
”
4-3/8
”
5/8
”
5-1/2
”
18
”
23-1/4
”
15/32
”
7-1/2
”
5-3/4
”
7/8
”
3-5/8
”
2-1/2
”
1-5/16
”
16-1/2
”
2VB
20
”
NOTE:
H.P. Exhaust Opening 3/4" Tubing.
Flywheel Rotation
– Clockwise when viewed from
front, flywheel to rear.
SPECIFICATIONS
MODEL
BORE & STROKE
(INCHES)
NO. OF
CYLINDERS
OIL CAPACITY
(QTS.)
WEIGHT
(LBS)
PRESSURE
(PSIG)
CU FT./REV.
MIN./MAX.
RPM
R15B
4-5/8 & 2-1/2 x 3
2
2
109
175
.02914
400/990
PERFORMANCE
PUMP
PRESSURE
(PSIG)
MOTOR
H.P.
PUMP
RPM
DISPLACEMENT
(CFM)
COOLING
AIR FLOW
(CFM)
HEAT
REJECTION
(BTU/HR)
APPROX.
PULLEY O.D.
(INCHES)
R15B
175
5
710
20.7
820
12,000
7.00
All data is based on 1725 RPM electric motors as a power source.
Pulley Dia. (approx.) = Compressor RPM x Flywheel Dia.
Motor or Engine RPM
C416-B
(Ref. Drawing)
Содержание CADRSASP12
Страница 10: ...9 FIGURE 1 DUPLEX CONTROL PANEL WIRING DIAGRAM ...
Страница 12: ...11 INSTALLATION CONT D CIRCUIT BREAKERS 1 Factory wired No wiring required Figure 3 Circuit Breaker ...
Страница 13: ...12 INSTALLATION CONT D MOTOR CONTACTORS 1 Factory wired No wiring required FIGURE 4 MOTOR CONTACTORS ...
Страница 15: ...14 INSTALLATION CONT D LOW OIL LEVEL MONITOR 1 Factory wired No wiring required FIGURE 6 LOW OIL LEVEL MONITOR ...
Страница 16: ...15 INSTALLATION CONT D ELECTRIC TANK DRAIN 1 Factory wired No wiring required FIGURE 7 ELECTRIC TANK DRAIN ...
Страница 25: ...24 PARTS ILLUSTRATION MODEL CADRSASP12 307CAD810 A Ref Drawing ...
Страница 27: ...26 DUPLEX CONTROL PANEL MOUNTING 305CAD810 A Ref Drawing ...
Страница 39: ...38 UNIT HAZARD DECALS ...
Страница 40: ...39 PUMP HAZARD DECALS F ...