No.
Part
Description
(a)
RA10
Motor
10Nm / 35mm
RA20
Motor
14Nm / 45mm
RA30
Motor
19Nm / 45mm
RA50
Motor
36Nm / 45mm
(b)
TAR40B
Adapter round, 40mm
TAP65B
Adapter profile, 65mm
TAO70B
Adapter octagonal, 70mm
TAM78B
Adapter awning, 78mm
TAM85B
Adapter awning, 85mm
(c)
WT840-2
Octagonal tube 40mm - 2m (40mm)
WT860-1
Octagonal tube 60mm - 1m
WT860-2
Octagonal tube 60mm - 2m
WT860-3
Octagonal tube 60mm - 3m
(d)
120995
Endcap for octagonal tube 60mm
(e)
121084
Opposite wallbearing for
octagonal tube 60mm
(f)
TCS1ED
Wall Switch (Rocker switch)
(g)
TCT2ED
Programmable Timer
TCTRX2ED
Programmable Timer with integrated
Receiver
TCTTX2ED
Programmable Timer with integrated
Transmitter
(h)
WTMZ1
Central Module
(i)
TCRX3ED
Rolling Shutter Remote Control
Receiver
(j)
TCTX2ED
Remote Control Wall Switch
TCRX2ED
Rolling Shutter Control with integrated
Receiver
(k)
WTMLS1
Light Sensor
(l)
TCLS1ED
Remote Control Light and
Glass Breakage Sensor
(m)
703280
Switch - flush mount
TROUBLE SHOOTING
Motor does not run
• Public electricity supply failure. Check with a neighbor.
• Fuse has tripped or is blown. Check house overload
protector. If necessary, have an authorized electrician
redistribute the load.
• The switch is defective. Have it checked by an authorized
electrician and replaced if necessary.
• Repeated operation may have tripped the motor overload
protector switch. Wait 15 minutes and try again.
Motor runs intermittently
• Have the wiring connection between switch and motor
checked by an authorized electrician. Replace if necessary.
Motor does not shut off
• Check to be sure tube adapter is positioned all the way up
to the stop on the tube.
• Check to be sure the motor has been inserted all the way
into the tube.
N
L1.2 (brown)
M
TM
L1.1 (black)
N (blue)
Main
230 V/50 Hz
PE (yellow-green)
2I
1I
PI
E
Der Sicherheitscode des Handsenders und
des Empfängers müsse
Der Code wird im Werk eingeste
Der Code kann individue
K1
K2
Control Cable
4 x 0,75
1 yellow-green
2 blue
3 black
4 brown
Equipment Grounding Conductor PE
Color Scale for Drive Table
Neutral MP
Phase Direction of Rotation 1
Phase Direction of Rotation 2
M
TM
J
Leftsided Installation 703280
9
L1.2 (brown)
L1.1 (black)
N (blue)
Main
230 V/50 Hz
PE (yellow-green)
2
ANTRIEB
L1 L1 MP PE
PE MP L1
V
VERSION
SROLO-06
ZUGANG
Steuerkabel
Eingangsspannung
Vom
Antrieb
M
braun
schwarz
braun
blau
blau
L1.2
L1.2
L1.1
MP
MP
PE
PE
gelb-grün
gelb-grün
Handsender
Der Sicherheitscode des Handsenders und
des Empfängers müssen übereinsti
Der Code wird im Werk eingeste
Der Code kann individuell geändert
Kanal
K1
K2
Control Cable
4 x 0,75
1 yellow-green
2 blue
3 black
4 brown
Equipment Grounding Conductor PE
Color Scale for Drive Table
Neutral MP
Phase Direction of Rotation 1
Phase Direction of Rotation 2
M
TM
K
Connection of the
Model TCS1ED switch
M
TM
L
leftsided
installation
0
4
5
6
7
1
10.7
10.4
10.10
10.5
10.10
10.8
5
L
10.7
07:00
>>
Enter
+-1h
IN
12
3
4
5
6
10
8
0
9
8
7
2
6
4
7
1
6
k
d
c
e
a
b
h
f
j
g
l
i
m
GB-4
709205B-GB
© Chamberlain GmbH, 2005