When an alarm is triggered, the system can activate (energize) one or more relays. A
relay can sound a siren, turn on a flashing red light, turn on a closed circuited
television (CCTV), or trigger other mechanisms.
Configure the Alarm Features
Features
Features
Page 54
Enable or Disable Anti-Passback Forgiveness at Midnight:
105
Press Then
If you Enable the anti-passback forgiveness feature, All entry codes, cards, transmitters
will be reset at midnight each day. The system will grant entry/exit and "forgive" any
errors from the previous day.
Factory Setting: Enabled
Enable (
1
) or Disable (
0
). Then (#)
Configure "Door Held Open" Alarm Feature:
102
Press Then
Enter Alarm Option (0-2). Then (#)
Option 0=
Disabled
Option 1=
Enabled
Relays will activate until relay
time expires
(See
Set Relay Activation Time
on page 23 (
Step 3
) for more information)
Option 2=
Enabled
Relays will activate until the
alarm condition clears
(e.g., the door is
closed from the "door held open" alarm condition)
Activate (1) or Deactivate (0) Relays (0000-1111). Then (#)
(1st digit=Relay 4, 2nd digit=Relay 3, etc.)
When
enabled
, doors can be programmed to trigger an alarm when they are held open
to long. The alarm will activate the relays you specify. The relays can remain active until
the relay time expires
or
until the alarm condition clears.
Factory Setting: Disabled
1
2
3
Example:
Relay 4
Deact Activate Deact Deact
Relay 3 Relay 2 Relay 1
When a "Door Held Open" alarm condition occurs, relay "3" will activate until the alarm
condition clears. If the alarm relay controls a flashing light, the light will turn off when
the door is closed.
1
2
1
2
3
Enable or Disable Utility Option:
58
Press Then
Enter Utility Option (0-3). Then (#)
Option 0=
Off
; Option 1=
Resets Daily
(number of uses resets to the original programmed
value everyday at midnight); Option 2=
Resets Weekly
(number of uses resets to the original
programmed value every week); Option 3=
Never Reset
(number of uses continue to
decrease until the value is 0-the number never resets)
1
2
Factory Setting: Disabled
NOTE:
The last option can be ignored if the
utility feature is currently OFF.