Access Cards
Access Cards
Add a Group of Cards at Once:
82
Press Then
Enter Card Number (1-65534 [26 or 30-bit]).
Then (#)
Enter Ending Card Number (1-65534 [26 or 30-
bit]). Then (#)
Enter Facility Code (0-63 [30-bit],
0-255 [26-bit]). Then (#)
Card Type (26 or 30). Then (#)
Activate (
1
) or Deactivate (
0
). Then (#)
This feature allows you to enter a large number of cards into the system at one time. Individual
cards from a group can be edited later. For example, you have 250 cards that you want to enter
into the system so that every time someone needs a card, you won’t have to program the
system individually to enter a new card.
3
4
NOTES:
• Group cards must be the
same Card Type
and have the
same Facility Code
. In addition, you may also
activate the cards, add a schedule to one or more doors. These options must also be the same.
• If you don’t add a Facility Code or Card Type when adding a new card group, the system will add the
defined default values. For details see Default Facility Code or Default Card Type on page 43.
Page 41
5
6
Schedule for Door 1 (0 to 63). Then (#)
0
=Full Restrictions
1
=Full Access
Schedule for Door 2 (0 to 63). Then (#)
0
=Full Restrictions
1
=Full Access
Schedule for Door 3 (0 to 63). Then (#)
0
=Full Restrictions
1
=Full Access
Schedule for Door 4 (0 to 63). Then (#)
0
=Full Restrictions
1
=Full Access
7
8
9
10
Factory Settings:
All Doors =
1 Full Access
1
2
Adds a inactive group of Cards that range between "21500" and "21600", default Facility Code,
30-bit Card Type, inactive, and valid at all doors.
c
A
d
Example:
1
2
3
4
5
6
7
8
9
10
Add or Edit a Full Function Card:
81
Press Then
Enter Card Number (1-65534 [26 or 30-bit]).
Then (#)
Enter Facility Code (0-63 [30-bit],
0-255 [26-bit]). Then (#)
Enter Card Type (26 or 30). Then (#)
Schedule for Door 1 (0-63). Then (#)
0
=Full Restrictions
1
=Full Access
When adding a full function card, it will default as "
Active
". To deactivate a code, or deactivate
on a specific time and date, see
Activate or Deactivate Card
on page 42.
3
4
Example:
Door 2
Door 1
3
4
5
6
Door 3
7
Door 4
8
2
1
NOTE:
For new cards, if you don’t add a Facility Code or Card Type, the system will add the defined default
values. For details, see Default Facility Code or Default Card Type on page 43.
NOTE:
To replace a lost card first delete the lost card (Step 88 on page 42) and then add the new card to the
unit’s database (Step 81 on this page).
NOTE:
The new card uses the default settings for active and inactive values. To modify these settings use
Step 87 on page 42.
5
Schedule for Door 2 (0-63). Then (#)
0
=Full Restrictions
1
=Full Access
Schedule for Door 3 (0-63). Then (#)
0
=Full Restrictions
1
=Full Access
Schedule for Door 4 (0-63). Then (#)
0
=Full Restrictions
1
=Full Access
6
7
8
Factory
Settings
All Doors =
1 Full Access
Adds card with number "12287", Facility Code "1", 30-bit Card Type, schedule "2", that opens door 1 ONLY
1
2
Содержание Elite EL Series
Страница 74: ...Page 73 Notes...
Страница 75: ...Page 74 Notes...
Страница 80: ...845 Larch Avenue Elmhurst Illinois 60125 1196 114A2954E 2006 The Chamberlain Group Inc All Rights Reserved...