28
Multi-Function Door Control (Optional)
OPERATION OF THE
MULTI-FUNCTION DOOR CONTROL
Press the push bar to open or
close the door. Press again to
reverse the door during the
closing cycle or to stop the
door while it
'
s opening.
Light feature
Press the Light button to turn the opener light on or off.
It will not control the opener lights when the door is in
motion. If you turn it on and then activate the opener,
the light will remain on for 4-1/2 minutes. Press again to
turn it off sooner. The 4-1/2 minute interval can be
changed to 1-1/2, 2-1/2, or 3-1/2 minutes as follows:
Press and hold the Lock button until the light blinks
(about 10 seconds). A single blink indicates that the
timer is reset to 1-1/2 minutes. Repeat the procedure
and the light will blink twice, resetting the timer to 2-1/2
minutes. Repeat again for a 3-1/2 minute interval, etc.,
up to a maximum of four blinks and 4-1/2 minutes.
Lock feature
Designed to prevent operation of the door from
hand-held remote controls. However, the door will open
and close from the Door Control, the Outside Keylock
and the Keyless Entry Accessories.
To activate, press and hold the
Lock button for 2 seconds. The
push bar light will flash as long
as the Lock feature is on.
To turn off, press and hold the
Lock button again for
2 seconds.The push bar light will
stop flashing. The Lock feature
will also turn off whenever the
“learn” button on the motor unit
panel is activated.
LOCK
LIGHT
Lighted
P
u
sh B
u
tton
Lock
B
u
tton
Light
B
u
tton
To prevent possible SERIOUS INJURY OR DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet, and away
from all moving parts of door.
• NEVER permit children to operate or play with door control
push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
WARNING
CAUTION
WARNING
WARNING
Opener Terminal Screws
2-Conductor
Bell
W
ire
Antenna
Opener Panel
Multi-Function
Door Control Panel
Terminal Screws
KG
KG
1
3
9
7
5
1
3
9
7
5
1
2
3
Door Control
Push Bar
Light Button
Lock
Button
LOCK
LIGHT
2
1
RED WHT
INSTALLATION
Locate door control within sight of the door at a
minimum height of 5 feet where small children cannot
reach, and away from moving parts of the door and
door hardware. If installing into drywall, drill 5/32" holes
and use anchors provided. For pre-wired installations
(as in new home construction), it may be mounted to a
single gang box.
NOTE:
After installation, a green
indicator light behind the cover will indicate proper
connection. If not lit, the Lock and Light features will not
function (reverse wires to correct).
1. Strip 1/4" of insulation from one end of bell wire and
connect to the two screw terminals on back of door
control by color: white wire to 2 and white/red
wire to 1.
2.
Remove white cover by gently prying on a side
corner near the top of the cover with a small flat
head screwdriver.
Fasten with 6ABx1-1/4
"self-tapping screws (standard installation) or 6-32x1"
machine screws (into gang box) as follows:
• Drill and install bottom screw, allowing 1/8" to
protrude above wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
• Install top screw with care to avoid cracking plastic
housing.
Do not overtighten.
• Insert bottom tabs and snap on cover. (To remove
cover after mounting, gently pry at top with paper
clip or small flat head screwdriver.)
3.
(Standard installation only)
Run bell wire up wall
and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit.
4. Connect bell wire to the opener terminal screws:
white to 2 and white/red to 1.
5. Use tacks or staples to permanently attach
entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.
NOTE:
DO NOT connect the power and operate the
opener at this time. The trolley will travel to the full open
position but will not return to the close position until the
sensor beam is connected and properly aligned. See
Safety Reversing Sensor Instructions beginning on
page 15.