24
To Open the Door Manually
The door should be fully
closed if possible. Pull down
on the emergency release
handle and lift the door
manually. To reconnect the
door to the opener, press the
door control push bar.
The
lockout feature
prevents
the trolley from reconnecting
automatically. Pull the
emergency release handle
down and back (toward the
opener). The door can then
be raised and lowered
manually as often as
necessary. To disengage the
lockout feature, pull the
handle straight down. The trolley will reconnect on
the
next UP or DO
WN
operation.
To prevent possible SERIOUS INJURY or DEATH from a
falling garage door:
• If possible, use emergency release handle to
disengage trolley ONLY when garage door is CLOSED.
Weak or broken springs or unbalanced door could
result in an open door falling rapidly and/or
unexpectedly.
• NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If
rope knot becomes untied, you could fall.
Trolley
Release
Arm
NOTIC
E
Emergency
Release
Handle
(P
u
ll Do
w
n)
Trolley
Release
Arm
NOTICE
Emergency
Release Handle
(Do
w
n and Back)
WARNING
CAUTION
WARNING
WARNING
LOCKOUT POSITION
MANUAL DISCONNECT
POSITION
CARE OF YOUR OPENER
LIMIT AND FORCE ADJUSTMENTS:
W
eather conditions may
cause some minor changes in
door operation requiring some
re-adjustments, particularly
during the first year of
operation.
Pages 21 and 22 refer to the
limit and force adjustments.
Only a screwdriver is required.
Follow the instructions
carefully.
Repeat the safety reverse test (Adjustment
Step 3, page 22) after any adjustment of limits
or force.
LIMIT CO
N
TROLS
(Left side panel)
FORCE CO
N
TROLS
(Back panel)
KG
KG
1
3
9
7
5
1
3
9
7
5
Open Force Close Force
Using the Wall-Mounted
Door Control
Press the push button to open or close
the door. Press again to reverse the door
during the closing cycle or to stop the
door while it
'
s opening.
MAINTENANCE SCHEDULE
Once a Month
• Manually operate door. If it is unbalanced or
binding, call a trained door systems technician.
• Check to be sure door opens & closes fully. Adjust
limits and/or force if necessary. (See pages 20
and 21.)
• Repeat the safety reverse test. Make any
necessary adjustments. (See Adjustment Step 3.)
Twice a Year
• Check chain tension. Disconnect trolley first. Adjust
if necessary (See page 7).
Once a Year
• Oil door rollers, bearings and hinges. The opener
does not require additional lubrication. Do not
grease the door tracks.