7.0 Appendix A - Maintenance Guide
16
1. Remove the right arch side panel.
2. Lift hood and place 5/8” (15.9 mm) thick material on the front edge of the table.
3. Loosen hood switch mounting screws.
4. Adjust the hood switch plunger to touch the steel actuator flap.
5. Tighten hood switch mounting screws.
6. Replace arch side panel.
7. Test according to instructions in Appendix D- Safety System Tests.
8. Fine-tune the actuator switch as required.
Figure 7- Hood Switch Adjustment
7.1.5 Hood Plunger Adjustment
1. Locate the spring plunger in the left hood pivot block.
2. Use a hex wrench to adjust the plunger until the hood remains in the up position.
Do not over-tighten the plunger. Over-tightening the plunger will cause undue wear.
7.1.6 Backgauge Preset Position Adjustment
Use the following instructions to set the forward backgauge limit to the preset position, 1.31” (3.3 cm):
1. Remove the rear Lexan™ cover.
2. Loosen the jam nut on the preset adjustment setscrew.
3. Adjust the setscrew until the test cuts result in a cut of 1.31” (3.3 cm).
4. Re-tighten jam nut.
5. Replace rear Lexan™ cover.
7.2 Hydraulic System
7.2.1 Hydraulic Fluid Check
The hydraulic fluid should be checked every six months and topped off as necessary. Depending on
usage, it may need to be checked more frequently.
To check the hydraulic fluid level:
Disconnect main power.
See Section 2.2 Power Lockout Procedure.
NOTICE: UNSUPPORTED PRODUCT!
NO TECHNICAL SUPPORT AVAILABLE!
NO REPAIR PARTS AVAILABLE!