Steps
Signal
1. Hold the System-Master in the reading field of the locking device for approx. 1 second.
‘Delete mode’ has been started.
1x
short green
2. Now you can delete any number of master media in succession by holding each master
medium in the reading field of the locking device for about 5 seconds.
The master medium has been deleted.
2x
short green
after each mas-
ter medium
3. Hold the System-Master in the reading field of the locking device for approx. 1 second.
‘Delete mode’ has been terminated.
1x
long green
‘Delete mode’ is terminated automatically after approx. 5 seconds. The master
media previously held up to the reading field are deleted from the locking device.
All master media that were held in the reading field are now no longer authorised to
implement settings for this locking device.
Troubleshooting:
Signal
Cause
Solution
After step 2:
2x
short red
The master medium cannot be deleted
because it is not one of the master media that
requires authorisation.
RF-Ini-Masters (for NET and VA devices) and
RF-Trace-Masters do not need to be author-
ised and therefore cannot be deleted.
1x
short green
The master medium was held in the reading
field of the locking device for too short a time.
The authorisation has not been deleted.
Hold the master medium in the reading
field of the locking device for a longer time.