7.2 How to connect the inputs and outputs
Please always note the instructions of third-party manufacturers when you connect their
devices.
The communication module is equipped with 4 inputs and 6 outputs
which can be connected by means of the screw terminals on the
right side of the circuit board.
7.2.1 Inputs
The communication module is equipped with 4 inputs labelled IN1 to
IN4.
Functions of the inputs
Input
Function
Reaction upon
activation
Reaction upon
deactivation
Remarks
IN1
Open
The order “Open” is sent to
the coupled lock
No reaction
If IN1 and IN2 are bridged so that both can
be switched simultaneously, they react as
follows:
- If both inputs are activated, the order
“Open” is sent to the coupled lock
- If both inputs are deactivated, the order
“Close” is sent to the coupled lock
IN2
Close
The order “Close” is sent to
the coupled lock
No reaction
IN3
Privacy
mode
The order “Privacy mode
ON” is sent to the coupled
lock
The order “Privacy mode
OFF” is sent to the coupled
lock
Please take note of the information on
IN4
Night
locking
mode
The order “Night locking
mode ON” is sent to the
coupled lock
The order “Night locking
mode OFF” is sent to the
coupled lock
The night locking mode is only relevant for
motor cylinders.
Please take note of the information on
"Night locking mode (only motor
CESeasy communication module
Page 15 of 37
7 Connections