7.2.2 Outputs
The communication module is equipped with 6 outputs
labelled OUT1 to OUT6.
Functions of the outputs
Output
Function
Activated by
Deactivated by
Remarks
OUT1
Batteries
nearly empty
Is activated if the
batteries of the
communication
module of the
coupled lock are
nearly empty.
Is deactivated if the battery voltage
of the communication module is
high again and the “Batteries nearly
empty” message of the coupled lock
has been reset.
OUT2
Communications
error
Is activated if it is
not possible to
establish wireless
communication
with the coupled
lock.
Is deactivated as soon as wireless
communication with the coupled
lock has been re-established.
The output status is updated
by controlling the
communication with the
coupled lock:
- Whenever orders are
exchanged between the
communication module and
the coupled lock.
- The connection is checked by
means of a polling procedure
once per minute.
OUT3
Privacy mode
active
Is activated if the
privacy mode is
activated.
Is deactivated if the privacy mode is
deactivated.
Please take note of the inform-
ation on
OUT4
Night locking
mode
active
Is activated if the
night locking mode
is activated.
Is deactivated if the night locking
mode is deactivated.
The night locking mode is only
relevant for motor cylinders.
Please take note of the
information on
OUT5
Door unlocked
Is activated if the
coupled lock
unlocks the door.
Is deactivated when “Open” has
been completed. This depends on
the lock settings (e.g. opening times
The locks have to meet the
following conditions:
- Motor cylinder: latch and
Page 18 of 37
CESeasy communication module
7 Connections