background image

12.2 Dimensions

Page 32 of 37

CESeasy communication module

12   Technical data

Содержание CESeasy 347102V

Страница 1: ...CESeasy Communication module Assembly and Operating Manual English Version VB BRO2280 2...

Страница 2: ...with batteries 7 4 CESeasy communication module 9 4 1 About communication modules 9 4 2 Scope of application 9 5 Scope of delivery 10 6 Assembly 11 7 Connections 14 7 1 How to connect the power suppl...

Страница 3: ...are 27 10 2 Reset of the communication module 27 11 Operation 29 11 1 Privacy mode 29 11 2 Night locking mode only motor cylinders 29 12 Technical data 31 12 1 Equipment features 31 12 2 Dimensions 32...

Страница 4: ...this manual is shown on the cover page You can get the latest version free of charge from www ces eu 1 1 Design characteristics Refers to other documents Marks additional information and tips Marks w...

Страница 5: ...ed by deficient assembly l Damage caused by deficient maintenance l Damage caused by false operation l Damage caused by overvoltage l Damage caused by fire water or smoke All technical data and featur...

Страница 6: ...nstitute function related hazards for the user or third parties and may impair the handle set and other material assets Please observe all warnings and notices in this manual while assembling configur...

Страница 7: ...mosphere chlorine ammonia lime water l Do not use the device in areas with high dust formation l Do not use the device near heat sources Please observe the maximum permissible temperatures and the inf...

Страница 8: ...ately from the device Clean the contacts before inserting new batteries There is danger of injury from battery acid l Remove the empty batteries from the device l Please take note of the information o...

Страница 9: ...e additional outputs which reflect the lock status The communication module and the lock communicate wirelessly 4 2 Scope of application Due to the available inputs and outputs and the functions which...

Страница 10: ...5 Scope of delivery 1 1 Communication module 2 2 Batteries 3 1 Power supply unit Page 10 of 37 CESeasy communication module 5 Scope of delivery...

Страница 11: ...e proximity These factors can absorb or reflect the radio signal which is why it is not possible to make a general statement about the maximum distance In most cases a distance of up to 10m within a b...

Страница 12: ...the communication module with at least two 4mm countersunk head screws to a level surface The length of the screws depends on the surface Depending on the surface you may have to use suitable dowels...

Страница 13: ...ing in the battery compartment which indicates the correct polarity 6 Link the communication module to your lock see How to couple a lock on page 24 7 Check if the communication module is working corr...

Страница 14: ...l marked 12VCD and GND Make sure to connect the power supply unit correctly to the positive and negative terminal Run the connecting cables through the recess of the case towards the outside Before co...

Страница 15: ...ched simultaneously they react as follows If both inputs are activated the order Open is sent to the coupled lock If both inputs are deactivated the order Close is sent to the coupled lock IN2 Close T...

Страница 16: ...1 afterwards still remains activated and e g a Close order is sent by the CESeasy app the lock will carry out the Close order but will not react to input 1 anymore although it is still active Only if...

Страница 17: ...nnected e g a switch or a relay As soon as the contact closes INx is con sidered to be active Example 2 Open collector output A Open collector output B Device with an output C Communication module A d...

Страница 18: ...d lock Whenever orders are exchanged between the communication module and the coupled lock The connection is checked by means of a polling procedure once per minute OUT3 Privacy mode active Is activat...

Страница 19: ...odule are open collector outputs which can switch max 150mA The maximum voltage is 28V An open collector output is not a potential free contact The output consists of a transistor semiconductor which...

Страница 20: ...back diode directly on the load The device may be damaged if no flyback diode has been used or if it was connected falsely Situation 2 Circuit with an input A Communication module B Device with an inp...

Страница 21: ...pply unit fails the communication module can continue to work for some days with a new set of batteries 8 3 Battery warnings If the batteries of the communication module are nearly empty the communica...

Страница 22: ...has to be switched on l Firmware has to be installed on the communication module see Firmware on page 27 1 Press the coupling button Now the red LED next to the coupling button indicates the battery s...

Страница 23: ...dule and pull off the cover 2 If necessary take out the two empty batteries Insert the two new batteries Please ensure that the batteries are inserted according to the labelling in the battery compart...

Страница 24: ...mpty to the communication module which then can be displayed by our third party device Only one lock one motor cylinder or door controller can be coupled to a communication module at the same time Pre...

Страница 25: ...firmware update Otherwise no device can be coupled to the communication module 2 Press the coupling button of the communication module for approx 1 second If the communication module was able to coupl...

Страница 26: ...er manual For the communication module By resetting the communication module see Reset of the communication module on the facing page 9 3 Coupling to a new lock You can couple the communication module...

Страница 27: ...ways compatible with the firmware in the lock Firmware updates l The firmware is always automatically updated after a lock has been coupled to the module see How to couple a lock on page 24 Consequent...

Страница 28: ...ommunication module back on by restoring the power supply with the power supply unit or by reinserting the batteries 4 Release the coupling button The coupled lock and the firmware have now been delet...

Страница 29: ...of the nursing service can no longer open your lock However your children can still open the lock because they have received the key directly from you When in privacy mode the lock can still be opene...

Страница 30: ...e g certain doors must not be locked When in night locking mode the motor prevents the knob from being manually turned by exerting force in the opposite direction This uses a lot of battery energy whi...

Страница 31: ...rs 6 outputs with standard assignment Maximum load 28V 150 mA RF Transceiver RF Transceiver 868 MHz for wireless communication with compatible CESeasy devices Encryption AES128 Service life Battery se...

Страница 32: ...12 2 Dimensions Page 32 of 37 CESeasy communication module 12 Technical data...

Страница 33: ...contaminants contained in them can lead to health and environmental hazards In addition appropriate disposal allows recovery and re use of recyclable materials which is a substantial contribution to m...

Страница 34: ...y Collection points for batteries and rechargeable batteries are identified by a variety of symbols Package Packaging of the components is made from environmentally friendly reusable materials In deta...

Страница 35: ...sumption 21 Battery replacement 23 D Declaration of conformity 6 E EU Declaration of conformity 6 F Flyback diode 20 N Night locking 29 Night locking mode 29 Night locking mode ON OFF 29 P Privacy mod...

Страница 36: ...S Safety instructions 6 Page 36 of 37 CESeasy communication module 14 Index...

Страница 37: ...com CESfrance SARL 8 Impasse Charles Petit F 75011 Paris 33 1 44 87 07 56 33 1 43 07 35 78 infofr ces eu Austria C sar A C rcamo B ro Wiener Bundesstrasse 33 A 4050 Traun 43 660 73 20 311 43 732 21 0...

Отзывы: