2.0
Warrior MU-9X15
The MU-9X15 receiver features 16 Form A relays arranged in four banks of four. Bank 1 through
Bank 3 each have three relays sharing a common fused at 5A. The fourth relay is independent
rated at 8 A @ 250 VAC. Bank 4 features one independent Horn/Light relay, two series relays
that form the Main Line Contact (MLC) output, and one Start relay. The Start and MLC circuits
share a common fused at 5 A (Reference Appendix C for details regarding MLC safety logic).
The independent relays (K13, K04, K08, K12) are rated at 8 A @ 250 VAC.
Figure 3. Bank Configuration
2.1
Input Voltages
Depending on the model, the MU-9X15 accepts the following input voltages:
•
110 to 220 VAC at 50
–60 Hz (High VAC)
•
10 to 28 VAC at 50
–60 Hz (Low VAC)
•
9 to 36 VDC