background image

System Manual  

©

2019

 

Cervis, Inc. 

17 

4.0 

Warrior MU-X15 System Operation 

4.1 

System Startup 

The following assumes that power is applied to the Warrior 
MU-9X15 receiver. 

1.  Press the handheld STOP button (B1). 

2.  Wait while the LEDs cycle and then the RX/TX LED 

begins flashing. 

3.  Press the Horn/Start button (B2). This energizes the 

MLC relays in the receiver. 

The handheld is ready for normal functional operation. 

4.2 

Associating a Handheld with a Receiver 

Warrior MU-X15 system handhelds are associated with the receiver before the system is 
shipped; and the Association process is locked by DIP switch 8 in the receiver being 0 (OFF). 
The receiver only communicates with handhelds it is associated with. When necessary, other 
Warrior handhelds can be associated with the receiver as additional spares or to replace 
damaged handhelds, 

but the receiver’s association ability must be unlocked first. 

There are two methods to unlock association:

  

1.  By manually changing the position of DIP switch 8 in the receiver. To unlock 

Association, DIP Switch 8 must be changed from its default position (0 [OFF]) to 
(1 [ON]). Unlocking with the DIP switch unlocks association until DIP switch 8 
changes back to the 0 (OFF) or LOCKED position. 

2.  By using an already associat

ed handheld and preforming a “virtual” UNLOCK. 

This process allows users to unlock the receiver from a distance without needing 
to access the receiver. A virtual unlock allows users to associate with the locked 
receiver for a limited time; after five minutes

—or after a successful handheld 

association

—the virtual unlock expires, and the receiver becomes locked again. 

4.2.1  Associating a Handheld Using the DIP Switch Unlock Option.  

This process will unlock association of the receiver allowing the user to associate handhelds to 
the receiver until the DIP switch is set back to the locked position.  

1.  Set the receiver SW01 DIP Switch 8 ON (UP).  

2.  If the receiver is 

Off

, the Horn/Light relay will activate when it is powered. If the receiver 

is 

On

, the Horn/Light relay will immediately activate. 

3.  Go to section 4.3 

 

Cervis, Inc. does not recommend leaving receivers in an 
UNLOCKED state. Move DIP switch 8 to the “0” (OFF) position 
once association is complete.  

 

 

Содержание Warrior MU-9X15

Страница 1: ...2019 Cervis Inc MU X15 System Manual U100 4 0...

Страница 2: ...Sant Canada pour la population g n rale consulter le Code de s curit 6 disponible sur le site Web de Sant Canada https www canada ca en health canada services environmental workplace health reports pu...

Страница 3: ...Handheld Remote HH2S 9XW10 14 3 1 HH2S 9XW10 Battery Installation 15 3 2 HH2S 9XW10 Battery Warning and Shutdown 16 4 0 Warrior MU X15 System Operation 17 4 1 System Startup 17 4 2 Associating a Handh...

Страница 4: ...Control Cable Internal Wiring Description 25 List of Tables Table 1 MU 9X15 Diagnostic LEDs 7 Table 2 MU 9X15 Power Configurations 9 Table 3 MU 9X15 Fuse Identification 11 Table 4 Switches 1 and 2 Mo...

Страница 5: ...ommunications technology Warrior Receiver Receiver mounted to the crane or machine Line of Sight aka Direct Line of Sight Term used to describe radio frequency RF communication where the pathway betwe...

Страница 6: ...ntil certain that it is safe to do so Turn off the handheld remote and remove power from the machine unit before attempting any maintenance This prevents accidental operation of the controlled machine...

Страница 7: ...ide variety of typical crane control applications Standard DIP Switch Set Configurations include 3 motion 2 speed control with A B Select configurations 3 motion 2 speed control with momentary or latc...

Страница 8: ...he handheld memory so that it will not control any receiver The Warrior MU X15 HH2S 9XW10 has four LEDs that identify system status and provide diagnostics LEDs as shown in Figure 2 are Transmit Recei...

Страница 9: ...ndent Horn Light relay two series relays that form the Main Line Contact MLC output and one Start relay The Start and MLC circuits share a common fused at 5 A Reference Appendix C for details regardin...

Страница 10: ...1 The MU 9X15 has one internal LED indicator used for association and health status visible from outside the enclosure The strobe LED can be shut off for one hour by pressing the shutoff switch see th...

Страница 11: ...nstallation to avoid injury Use the configuration diagrams supplied by Cervis Inc to guide you in mounting the receiver and connecting your wire harness Receiver mounting is left much to your discreti...

Страница 12: ...U100 5 0 8 Figure 5 MU 9X15 Mounting Dimensions...

Страница 13: ...ge Frequency MU 9X15 HVA High Voltage AC 115 230 Vrms 50 60 Hz MU 9X15 LVA Low Voltage AC 10 28 Vrms 50 60 Hz MU 9X15 LVD DC 7 36 V 2 5 MU 9X15 External Antenna The Warrior MU 9X15 comes with a 900 MH...

Страница 14: ...X15 Cable and Field Wiring Note The control cable is individually marked on the insulation of each wire Negative VDC VDC should be connected directly to the power supply negative terminal Figure 7 MU...

Страница 15: ...igure 8 MU 9X15 SW01 DIP Switch Assignments 2 9 MU 9X15 Mode Definitions Table 4 Switches 1 and 2 Mode Configurations Mode Definition 00 3 Motion Bridge Trolley and Hoist 3 relays A B and AUX function...

Страница 16: ...inition AB MOM LAT 0 HH A and B are momentary outputs MCB No effect 1 HH A and B are latching outputs MCB No effect Table 8 DIP Switch 6 Only Applies in Mode 00 HH AB CYC IND Needs Set to 0 Name Set D...

Страница 17: ...able 11 Table 10 Abbreviation Key Abbreviation Key BF Bridge Forward BR Bridge Reverse B2 Bridge Second Speed A Crane A Control TF Trolley Forward TR Trolley Reverse T2 Trolley Second Speed B Crane B...

Страница 18: ...ing to IEC 60529 The HH2S 9XW10 has four LEDs used for diagnostics that indicate wireless link transmit receive Battery and A B selection Figure 9 HH2S 9XW10 and LED Descriptions HH2S 9XW10 handheld r...

Страница 19: ...the cover from the handheld The screws remain attached to the cover Make sure the compartment sealing gasket stays in place on the handheld 2 Install two fresh size AAA batteries Be sure to position...

Страница 20: ...situation is present Replace them with two fresh AAA batteries as soon as possible The LED will flash at one second intervals until the batteries are changed or until the voltage level drops to 2 0 V...

Страница 21: ...ver To unlock Association DIP Switch 8 must be changed from its default position 0 OFF to 1 ON Unlocking with the DIP switch unlocks association until DIP switch 8 changes back to the 0 OFF or LOCKED...

Страница 22: ...e the B Select LED is active simultaneously press and release buttons A B and AUX 2 Handheld LEDs will begin cycling indicating the handheld is in maintenance mode 3 Simultaneously press and hold butt...

Страница 23: ...System Manual 2019 Cervis Inc 19 indicating communication is established The selected receiver is stored in the handheld memory slot...

Страница 24: ...held by pressing and releasing button 1 STOP 2 Within 1s of activating the handheld while only LED 4 is active simultaneously press and release buttons 9 and 10 The LEDs will start scrolling indicatin...

Страница 25: ...sing Radio Frequency 906 924 MHz 100mW License No license required Modulation Channel Hopping DSSS Antenna External RP TNC Enclosure Dimensions mm 200 x 150 x 100 Inches 7 87 x 5 9 x 3 93 Weight 1 5 l...

Страница 26: ...nse required Modulation Channel Hopping DSSS Antenna Internal Enclosure Dimensions mm 136 38 x 68 96 x 28 42 Inches 5 37 x 2 68 x 0 92 Weight 200 g 7 2 oz With lanyard or belt clip Durability High Imp...

Страница 27: ...he torso Equipment containing the radio module was evaluated for RF exposure hazards by two approaches 1 Maximum Permissible Exposure MPE for mobile applications 2 Specific Absorption Rate SAR for por...

Страница 28: ...r signal immediately causes the MLC path to open and all output relays to de energize If there is a software fault in the microprocessor the watchdog will not assert its enable output which will cause...

Страница 29: ...System Manual 2019 Cervis Inc 25 Appendix D MU 9X15 Control Cable Internal Wiring Diagram Figure 14 MU 9X15 Control Cable Internal Wiring Description...

Страница 30: ...connector to the receiver pigtail TS2L 2 pole Transfer Switch only Includes G4 02A 2 ea G4 02B TS 6P 1 Pre wired external Transfer Switch Assy up to 6 circuits Table 16 Aftermarket Support Spare Parts...

Страница 31: ...System Manual 2019 Cervis Inc 27 Visit our Web site at www cervisinc com 2019 Cervis Inc All rights reserved Content is subject to change without notice...