Appendix A: Exposure to Radio Frequency Energy 

Warrior system transmitter and receiver units contain radio transceivers. When active, 
transmitters/receivers send out radio frequency (RF) energy through an internal (or external) 
antenna. The Warrior Locomotive CB transmitter complies with limits set by the FCC for 
operating distance from human tissue

.

 

Appendix B: RF Exposure Considerations 

Radio modules may be used in a variety of host applications falling into two general categories: 

1. 

Mobile

 applications: Any operating locations where the transmitting equipment is 

not

 on 

a human body. In mobile applications, the host application is typically fixed to mobile 
equipment, with either an internal or external antenna. 

2. 

Portable

 applications: Any operating locations where the transmitting equipment 

is

 

located on the hand, arm, or other part of the human body. In portable applications, the 
equipment is either held in the hands of an operator or affixed to either a belt or harness 
on the torso. 

Equipment containing the radio module was evaluated for RF exposure hazards by two 
approaches: 

1.  Maximum Permissible Exposure (MPE) for mobile applications. 

2.  Specific Absorption Rate (SAR) for portable applications. 

Required separation distances are measured from the actual location of the radiating part of the 
antenna. An antenna may be inside the host application, affixed to the host application 
enclosure, or at the end of an optional extension coaxial cable. 

Mobile Applications

 

Equipment must be located in a location at least 20 cm away from areas likely to be occupied by 
an unaware person. 

Handheld Applications

 

All operators of the handheld equipment with any type of antenna require training in the proper 
operation of the equipment and such training must include RF exposure safety instructions. 
Once training is completed, they are considered to be aware persons. 

If the portable operating pose in on the hand or arm, a 5-mm separation is required between the 
radiating part of the antenna and nearby human tissue. 

Required Training

 

All installers and operators of host applications that include an SRF310 FT module 

must

 be 

trained to use proper RF safety precautions as presented in this section. 

Содержание Warrior MU-9X15

Страница 1: ...2019 Cervis Inc MU X15 System Manual U100 4 0...

Страница 2: ...Sant Canada pour la population g n rale consulter le Code de s curit 6 disponible sur le site Web de Sant Canada https www canada ca en health canada services environmental workplace health reports pu...

Страница 3: ...Handheld Remote HH2S 9XW10 14 3 1 HH2S 9XW10 Battery Installation 15 3 2 HH2S 9XW10 Battery Warning and Shutdown 16 4 0 Warrior MU X15 System Operation 17 4 1 System Startup 17 4 2 Associating a Handh...

Страница 4: ...Control Cable Internal Wiring Description 25 List of Tables Table 1 MU 9X15 Diagnostic LEDs 7 Table 2 MU 9X15 Power Configurations 9 Table 3 MU 9X15 Fuse Identification 11 Table 4 Switches 1 and 2 Mo...

Страница 5: ...ommunications technology Warrior Receiver Receiver mounted to the crane or machine Line of Sight aka Direct Line of Sight Term used to describe radio frequency RF communication where the pathway betwe...

Страница 6: ...ntil certain that it is safe to do so Turn off the handheld remote and remove power from the machine unit before attempting any maintenance This prevents accidental operation of the controlled machine...

Страница 7: ...ide variety of typical crane control applications Standard DIP Switch Set Configurations include 3 motion 2 speed control with A B Select configurations 3 motion 2 speed control with momentary or latc...

Страница 8: ...he handheld memory so that it will not control any receiver The Warrior MU X15 HH2S 9XW10 has four LEDs that identify system status and provide diagnostics LEDs as shown in Figure 2 are Transmit Recei...

Страница 9: ...ndent Horn Light relay two series relays that form the Main Line Contact MLC output and one Start relay The Start and MLC circuits share a common fused at 5 A Reference Appendix C for details regardin...

Страница 10: ...1 The MU 9X15 has one internal LED indicator used for association and health status visible from outside the enclosure The strobe LED can be shut off for one hour by pressing the shutoff switch see th...

Страница 11: ...nstallation to avoid injury Use the configuration diagrams supplied by Cervis Inc to guide you in mounting the receiver and connecting your wire harness Receiver mounting is left much to your discreti...

Страница 12: ...U100 5 0 8 Figure 5 MU 9X15 Mounting Dimensions...

Страница 13: ...ge Frequency MU 9X15 HVA High Voltage AC 115 230 Vrms 50 60 Hz MU 9X15 LVA Low Voltage AC 10 28 Vrms 50 60 Hz MU 9X15 LVD DC 7 36 V 2 5 MU 9X15 External Antenna The Warrior MU 9X15 comes with a 900 MH...

Страница 14: ...X15 Cable and Field Wiring Note The control cable is individually marked on the insulation of each wire Negative VDC VDC should be connected directly to the power supply negative terminal Figure 7 MU...

Страница 15: ...igure 8 MU 9X15 SW01 DIP Switch Assignments 2 9 MU 9X15 Mode Definitions Table 4 Switches 1 and 2 Mode Configurations Mode Definition 00 3 Motion Bridge Trolley and Hoist 3 relays A B and AUX function...

Страница 16: ...inition AB MOM LAT 0 HH A and B are momentary outputs MCB No effect 1 HH A and B are latching outputs MCB No effect Table 8 DIP Switch 6 Only Applies in Mode 00 HH AB CYC IND Needs Set to 0 Name Set D...

Страница 17: ...able 11 Table 10 Abbreviation Key Abbreviation Key BF Bridge Forward BR Bridge Reverse B2 Bridge Second Speed A Crane A Control TF Trolley Forward TR Trolley Reverse T2 Trolley Second Speed B Crane B...

Страница 18: ...ing to IEC 60529 The HH2S 9XW10 has four LEDs used for diagnostics that indicate wireless link transmit receive Battery and A B selection Figure 9 HH2S 9XW10 and LED Descriptions HH2S 9XW10 handheld r...

Страница 19: ...the cover from the handheld The screws remain attached to the cover Make sure the compartment sealing gasket stays in place on the handheld 2 Install two fresh size AAA batteries Be sure to position...

Страница 20: ...situation is present Replace them with two fresh AAA batteries as soon as possible The LED will flash at one second intervals until the batteries are changed or until the voltage level drops to 2 0 V...

Страница 21: ...ver To unlock Association DIP Switch 8 must be changed from its default position 0 OFF to 1 ON Unlocking with the DIP switch unlocks association until DIP switch 8 changes back to the 0 OFF or LOCKED...

Страница 22: ...e the B Select LED is active simultaneously press and release buttons A B and AUX 2 Handheld LEDs will begin cycling indicating the handheld is in maintenance mode 3 Simultaneously press and hold butt...

Страница 23: ...System Manual 2019 Cervis Inc 19 indicating communication is established The selected receiver is stored in the handheld memory slot...

Страница 24: ...held by pressing and releasing button 1 STOP 2 Within 1s of activating the handheld while only LED 4 is active simultaneously press and release buttons 9 and 10 The LEDs will start scrolling indicatin...

Страница 25: ...sing Radio Frequency 906 924 MHz 100mW License No license required Modulation Channel Hopping DSSS Antenna External RP TNC Enclosure Dimensions mm 200 x 150 x 100 Inches 7 87 x 5 9 x 3 93 Weight 1 5 l...

Страница 26: ...nse required Modulation Channel Hopping DSSS Antenna Internal Enclosure Dimensions mm 136 38 x 68 96 x 28 42 Inches 5 37 x 2 68 x 0 92 Weight 200 g 7 2 oz With lanyard or belt clip Durability High Imp...

Страница 27: ...he torso Equipment containing the radio module was evaluated for RF exposure hazards by two approaches 1 Maximum Permissible Exposure MPE for mobile applications 2 Specific Absorption Rate SAR for por...

Страница 28: ...r signal immediately causes the MLC path to open and all output relays to de energize If there is a software fault in the microprocessor the watchdog will not assert its enable output which will cause...

Страница 29: ...System Manual 2019 Cervis Inc 25 Appendix D MU 9X15 Control Cable Internal Wiring Diagram Figure 14 MU 9X15 Control Cable Internal Wiring Description...

Страница 30: ...connector to the receiver pigtail TS2L 2 pole Transfer Switch only Includes G4 02A 2 ea G4 02B TS 6P 1 Pre wired external Transfer Switch Assy up to 6 circuits Table 16 Aftermarket Support Spare Parts...

Страница 31: ...System Manual 2019 Cervis Inc 27 Visit our Web site at www cervisinc com 2019 Cervis Inc All rights reserved Content is subject to change without notice...