FibeAir® IP-20E
Installation Guide
Ceragon Proprietary and Confidential
Page 15 of 52
2.7
Antenna Connection
IP-20E can be mounted directly using the following antenna types:
MTI
Andrew: VHLP series
Note!
Appropriate lubricant or grease can be applied to the
screws that connect the IP-20E to the antenna interface.
2.8
Power Specifications
2.8.1
Important Notes!
The unit must only be installed by service personnel.
The unit must have a permanent connection to protective grounding.
Data port 2, Data port 3 ,the Management port, and the TNC connector do
not provide protection from over-voltages on telecommunication
networks for host equipment users.
The RSL interface connector is intended for technician use only.
Disconnect device (circuit breaker) in the building installation:
Shall be readily accessible and incorporated external to the equipment.
The maximum rating of the overcurrent protection shall be up to 6 Amp.
2.9
Environmental Specifications
Operating: ETSI EN 300 019-1-4 Class 4.1
Temperature range for continuous operating temperature with high
reliability:
-33°C (-27°F) to +55°C (131°F)
Temperature range for exceptional temperatures; tested successfully, with
limited margins:
-45°C (-49°F) to +60°C (140°F)
Humidity:
5%RH to 100%RH
IEC529 IP66
Storage: ETSI EN 300 019-1-1 Class 1.2
Transportation: ETSI EN 300 019-1-2 Class 2.3