CW2900 Installation and Operation Manual
48
Appendix 2: Installing the Fresh Air Intake Kit (AC01298)
Note: Only remove the knock-out that will be connected to the fresh air inlet.
To install a fresh air intake kit to the insert, the purchase of accessory AC01298 is
required.
Using pliers, remove the rectangular knock-out plate (A) located on the left or right side of
the convection air jacket. Choose the side that is best for your installation. Then, install the
fresh air kit adapter (B) using 4 screws (C). Secure the flexible pipe (E) (part #AC02090
not supplied) to the adapter (B) using one of the adjustable pipe clamps (D). Secure the
other end of the pipe to the outside wall termination (F) using the second adjustable pipe
clamp (D). The outside wall termination (F) must be installed outside of the building.