Page 49
Time-barring of a CENTURION NOVA code-hopping transmitter is
specified at the time of coding the transmitter into the system. Once
an RF input is defined as time-barred, any time-barred transmitter
associated with that input will be time-barred during the relevant
Time-period. If a physical or RF input is currently time-barred, any
attempt to activate it will be acknowledged by a short beep of the
onboard buzzer. The input, however, will not activate
!
Exclusions
Exclusions are used to prevent scheduled Time-periods from occurring at
specific times (eg. public holidays). While time-barring can be used to
achieve a similar end, exclusions can also be used to exclude time-barring
itself. Each exclusion consumes one Time-period. Exclusions have the highest
precedence, followed by time-barring and then Auto-functions
Menu 9 - General settings
Menu 10: Remote controls
!
Operating Standard
Configure the controller to conform to the specific region’s standard - e.g. UL325
or CE.
!
Reset options
!
Factory Defaults
- Restore only defaults for the operating standard / profile
chosen, no other settings affected
!
Delete All Remotes
- Delete all the remotes stored in the system; no other
settings affected
!
Reset All
– Clears the controller completely as per an off-the-production-line
unit
Boom pole end-of-travel limits are not affected by any reset
!
Diagnostic Screen
Allows a diagnostic screen to be displayed.
!
Round Test Button
Disables operation of the round test button on the controller
Learn up to 500 CENTURION NOVA remote control transmitter buttons. Using one
button as a shift button, each transmitter can operate up to six functions. Each
transmitter learned into the system is assigned a unique transmitter ID. When
adding transmitters, it is recommended that a record be kept of the ID number
allocated by the system to each respective transmitter and the person to whom
the transmitter is given. This is necessary should selective deletion be required at
a later stage.
&
Press button of valid transmitter
If the
remote controls menu
has been locked as discussed later, only by
pressing a button of a transmitter learned into the system, can this
remote
controls menu
be accessed
Содержание SECTOR 3
Страница 1: ...SECTOR installation manual HIGH VOLUME INDUSTRIAL TRAFFIC BARRIER TM...
Страница 67: ...Notes...
Страница 68: ...www centsys com 0 07 A 0012 SECTOR Installation manual...