23
Errors
Error
Boiler status
safety thermostat error
ERROR E-09
CAN’T WORK
What to do?
Possible causes:
Press „OK” button to confirm error. Wait for boiler temp. to fall down and manually reset safety thermostat (see part
"SAFETY THERMOSTAT"). Clean the boiler. Check working of the pumps. If error continous to occur, contact
authorized serviceman.
Activation of the safety thermostat due to boiler overheating.
Error
Boiler status
unknown boiler power
ERROR E-10
What to do?
Possible causes:
Contact authorized serviceman.Check if code key is installed. Install correct code key.
Missing boiler code key.
Error
Boiler status
wrong boiler power
ERROR E-11
What to do?
Possible causes:
Contact authorized serviceman. Install correct code key.
Installation of the wrong code key.
CAN’T WORK
CAN’T WORK
Technical instructions REGULATION
BioTec-C