CNC10 CENTROID CONTROL DP-7 PROBE PARAMETERS
Parameter Setting
(mm)
Description
3
0
Modal Tool and Height Offset Control
10
16
Enables decel on probe contact
11
14
Probe / TT PLC probe input number
12
10
Tool library number for probe
13
0.030 (0.762)
Clearance amount nominal
14
30
(762)
Fast Probing Rate
15
3
(76.2)
Slow Probing Rate
16
5
(127)
Maximum Search Distance
18
15
PLC input, Probe Detect, Spindle Inhibit
120
0.030 (0.762)
Probe stuck clearance amount
121
0.030 (0.762)
Grid digitizing minimum Z pullback
122
0.0002(0.0051)
Grid digitizing dead band distance
123
0
Radial clearance move
151
0
Repeatability tolerance
155
2
Probe type enable
186
0
Probe stuck retry disable
366
1
Probe Deceleration Multiplier
392
0.030 (0.762)
DP-7 Probe clearance pull-back
393
10
(254)
DP-7 Probe pull-back speed
394
10
(254)
DP-7 measuring feed rate
395
30
(762)
DP-7 set-up traverse feed rate
396
30
(762)
DP-7 set-up plunge feed rate
(see control manual for additional information)
COMMUNICATION CHECK:
Confirm probe is communicating with control. Press <Alt+I> to open the centroid PLC I/O
diagnostic screen. Locate the inputs entered in parameters 11 and 18 typically these are PLC
inputs 14 and 15. Verify that they change correctly when the probe is first connected. 15 will
turn on solid green and 14 will flash alternately red green then stay red. Also check for a
flashing red LED on the CPU10B daughter card. When the DP-7 is first connected it will flash
its outputs and LED indicator light as a diagnostic tool. The corresponding inputs on the
control should change (flash) as well.
UPGRADING FROM DP-4:
To upgrade from DP-4 the following hardware items are required:
1) Swap out CPU10B motion control card with daughter card
2) Swap out PLC RTK3
3) DSP conduit cable
4) Digitizing harness for RTK3 w/splice connectors
5) Software updates