10
ENGLISH
6. FAULT DIAGNOSIS
If the pump still does not operate correctly, please return it to
Cembre
(see §
7
page 34).
SYMPTOM
POSSIBLE CAUSES
REMEDY
The pump does not start when
the remote controller push button
is pressed.
F1 and F2 fuses are faulty.
Replace the fuses with equivalents.
Incorrect connection of the remote
controller plug or the mains cable
plug.
Connect plug correctly (see
§ 3.1
).
The pump starts but immediately
stops.
Incorrect connection of the hydraulic
hose.
Check the quick coupler for correct
connection (see
§ 3.1
).
The pump starts but the oil is not
pressurised and the yellow led
fl ashes.
Insuffi
cient oil in the reservoir.
Top up the oil reservoir (see
§ 3.3
and 5.1
).
Oil leaks in the hydraulic circuit.
Check the hydraulic connection
(see
§ 3.1
).
After long use the pump will not
start and the yellow led is on.
The thermal protection has triggered
because of motor overheating.
Allow the motor to rest and wait
until the motor has cooled down.
(see
§ 3.3
).
It is not possible to couple the
fl exible hose to the pump.
Residual oil pressure in the hose.
Connect the fl exible hose to the
pump keeping the release button
(PS) pushed.
Содержание CPE-1
Страница 4: ...4 IM FIG 1 PUMP POMPE PUMPE BOMBA POMPA IR TF CA MT QE PO LA C IG PS F PF PC...
Страница 37: ...37 FIG 6 TL FIG 7 TV...