www.cellarcool.com | Page 43
CM2500
The User Menu is accessed by pressing and holding the SET button for 3 seconds. Use the UP and DOWN ARROW
buttons to navigate to desired parameters. Press the SET button again to view these parameters. Press the UP and
DOWN ARROW buttons to adjust a parameter.
The following parameters are available in the menu:
Parameter
Description
Fdc - humidity enhancement
This parameter is measured in minutes, and is preset at the
factory to 1. An increase in this parameter will increase the humidity
enhancement of your cellar. This parameter should not be adjusted
to zero. Adjustments should be made in increments of 5, with a
maximum of 15 and a minimum of 1. After making any adjustments
to humidity enhancement, you should wait a minimum of 3 days
before making any additional adjustments. This will allow sufficient
time for the cellar to acclimate to the new setting.
FOF - “fan off”
This setting controls how long the fan stays off after the set point
has been reached. It is preset to 15 minutes. This setting should
not be adjusted, as most properly constructed wine cellars retain
an ample amount of humidity during the “fan off” cycle. If, however,
you wish to decrease the duration of the “fan off” cycle (in order to
increase the wine cellar’s relative humidity), you can adjust this
setting in the User Menu.
Fon - “fan on”
The “fan on” time is preset to zero minutes. This keeps the relative
humidity of the wine cellar at a stable level. If, however, you wish
to raise the relative humidity of your wine cellar, you can increase
the duration of the “fan on” cycle in increments of five (5, 10, or 15
minutes). After making any adjustment to the “fan on” cycle, you
should wait a minimum of 3 days before making any additional
adjustments. This will allow sufficient time for the cellar to acclimate
to the new setting.
CA1 - bottle probe (Pb1) calibration
CA1 - bottle probe (Pb1) calibration: You may use this parameter
to calibrate the bottle probe to a known temperature. This param-
eter can be adjusted between -12°F and 12°F. For example, if the
bottle probe temperature is 58°F, and the known temperature is
55°F, you can set the CA1 parameter to -3°F to match the known
temperature.
PA2 - installer menu
This menu is only accessible using a password and is not available
for adjustment.
USER MENU