Installation and operation manual
ELS 300
© CEDES/October 2016
www.cedes.com
7
6.
Application with Y-switches
Warning:
This application must not be used for Cat. 2 applications, according EN ISO 13849-1:2015.
Through the use of Y-switches, the wiring will be simplified. The outputs of the connected Rx will be summarized
to one output-signal. It will almost be like a customized light curtain with a single output signal.
Interconnection
0.25 m
Interconnection
0.25 m
Interconnection
0.25 m
Interconnection
0.25 m
Rx cable 5 / 10 / 20 m
Rx cable 5 / 10 / 20 m
Brown Blue Black
Out
Figure 7: ELS 300 network connection diagram
For PNP-networks, there is a Y-switch with
a green LED for power control and an
amber LED for showing the output state
available. This Y-switch with LEDs can
only be used with PNP-types.
Important:
In one network, all Rx have to be from the
same type (e.g. ELS 300 Rx-PNP/DO-N)
6.1. Output current
The max. output current depends on the network. If the output of one ELS 300 Rx in the network is active, the
status LEDs of all other Rx in the network light up.
Because of this, the output current depends on the number of connected Rx and of the Y-switch used.
Max. output current
=
50 mA - (n
Rx
x 2 mA + n
YLED
x 2.5 mA)
n
Rx
= Number of Rx (max. 7)
n
YLED
= Number of Y-switches with LED
Example - calculation of max. output current:
Network with six sensors as in Figure 7
è
50 mA - (6 x 2 mA + 4 x 2.5 mA)
28 mA = max. output current
6.2. Output characteristics by using Y-switch
Light beam
System 1
Light beam
System 2
Light beam
System 3
Output ELS 300
Rx- PNP/DO-
…
Ausgang ELS 300
Rx- NPN/DO-
…
Output ELS 300
Rx- PNP/LO-
…
Output ELS 300
Rx- NPN/LO-
…
HIGH
LOW
HIGH
LOW
HIGH
LOW
HIGH
LOW
Uninterrupted
Inter-
rupted
Uninterrupted
Inter-
rupted
Uninterrupted
Uninterrupted
Uninterrupted
Uninterrupted
Inter-
rupted
Inter-
rupted
Inter-
rupted
Inter-
rupted
Output
DO types
Output 1
or
Output 2
or
Output 3
LO types
Output 1
and
Output 2
and
Output 3
Figure 8: ELS 300 output characteristics