6
Cecilware
®
Water Boilers
Thermostat Adjustment
The Thermostat is factory set for proper dispense
temperature of 200°F ± 3°F (93°C ± 16°C) with the
control knob set to the maximum clockwise position. If
field adjustments are needed proceed as follows:
•
To DECREASE temperature
, turn the control knob
slightly in the COUNTERCLOCKWISE direction.
• To INCREASE the water temperature -
1. With the Thermostat Knob to its maximum
clockwise position, remove the knob and locate the
slotted adjustment screw inside the hollow
thermostat shaft.
2. Using a narrow-bladed screwdriver, engage slotted
adjustment screw and turn it 1/4 turn slowly
counter-clockwise.
3. Allow a few minutes for the temperature to reach
set level. The Heater Light will go ON, indicating the
heating element is activated, wait for it to go OFF,
indicating that the water has reached new set
temperature.
4. Take a temperature reading and repeat if necessary.
Adjustments
WARNING: SHOCK AND BURN HAZARD
To prevent electric shock and burn hazard this
procedure must be performed by a trained and
qualified service technician.
WARNING: SHOCK HAZARD
Disconnect power before attempting any electrical
repairs.
Thermostat Adjustment
Thermostat Bulb
Coupling
Nut
CCW - Decrease
Temperature
Содержание CME10E-N
Страница 9: ...Water Boilers Cecilware 9 Parts Diagram...
Страница 10: ...10 Cecilware Water Boilers Wiring Diagram...
Страница 11: ...Water Boilers Cecilware 11 Wiring Diagram continued...
Страница 12: ...12 Cecilware Water Boilers Wiring Diagram continued...
Страница 14: ...14 Cecilware Water Boilers...
Страница 15: ...Water Boilers Cecilware 15...