Maintenance (continued)

Component Tests

Water Inlet Valve Test

1. Turn power OFF. If the water level rises inside a

partially filled tank, the Water Inlet Valve is leaking.  

2. Disconnect wires from the Water Inlet Valve coil and

connect a 2 wire line cord to the terminals. Plug it
into a 120V outlet. If water flows in and stops when
you pull it out, the Valve is working fine. Repeat this
test a few times. The problem may be in the Probe
or Water Level Control Board. 

3. If the water does not flow in when the cord is

plugged into an electrical outlet, the Solenoid coil
may be damaged, opened, or the valve may have
an obstruction preventing the water from flowing in.
Clean or replace it.

Dual Probe Test

If lack of water persists, check the probe as follows:

1. Turn on the power and water supply. Check inside

the tank to make sure the water is below the Probe.
Pull the BLUE wire and terminal OFF the Probe rod.  

2. If water still does not flow after the wire is

disconnected from the Probe, the problem may be
in the Solid State Dual Level Control Board.

3. If water starts flowing into the tank, the Probe may

be grounded, due to excessive liming. Check with
Ohm meter.

4. Clean or replace probe.

Dual Probe Liquid Level Controller Test

Check the Controller as follows:
1. Make sure there is power input to the Controller at

the terminals AC1 & AC2. Your voltmeter should
read 115 Volts. It should read the same at terminals
AC1 & FILL when the water level is low. This is the
output power to actuate the coil of the Solenoid
Valve to open it. 

2. The lack of voltage at terminals AC1 & L-LEVEL or

H-LEVEL indicates that the Controller is not working
properly.

3. Make sure all wire connections are tight, including

ground.

4. If after this, the Controller is still failing to open the

Water Inlet Valve, replace it.

Hose Nut Assembly

Blue

WARNING: SHOCK AND BURN HAZARD

To prevent electric shock and burn hazard all tasks
described in this section are to be performed by a
trained and qualified service technician.

WARNING: SHOCK HAZARD

Disconnect power before attempting any electrical
repairs.

Содержание CME10E-N

Страница 1: ...9 Wiring Diagram 10 Thank you for purchasing this quality boiler For your safety and the safety of others read all warnings and the operator manual before installing or using the product Properly inst...

Страница 2: ...ock damage unit and will void warranty To reduce risk of explosion or fire do not use near combustibles WARNING Safety Information 2 Cecilware Water Boilers Important Safety Information This is the sa...

Страница 3: ...300 25 5 1 10 AWG 240 10 500 25 3 10 AWG 208 7 900 22 3 10 AWG NOTE 1 FIELD WIRING MUST BE SUITABLE FOR 75 DEGREES CELSIUS 2 USE COPPER WIRE ONLY FOR POWER SUPPLY CONNECTION 3 120 VOLT UNITS SUPPLIED...

Страница 4: ...ce such as a double check valve to be installed between the machine and the water supply Incoming pressure should be greater than 30 psi and not more than 70 psi NOTICE Connecting the water boiler to...

Страница 5: ...nit with a damp cloth using soap solution or a non abrasive compound when required Sanitizing 1 With power to the unit disconnected fill unit to capacity 2 Prepare a sanitizing solution in accordance...

Страница 6: ...stat shaft 2 Using a narrow bladed screwdriver engage slotted adjustment screw and turn it 1 4 turn slowly counter clockwise 3 Allow a few minutes for the temperature to reach set level The Heater Lig...

Страница 7: ...NOT TURN ON THERMOSTAT UNTIL BOILER IS PRIMED Replacing Thermostat Thermostat is located in side box of boiler Lift off side box door to gain access to thermostat then follow instructions below 1 Shut...

Страница 8: ...ll does not flow after the wire is disconnected from the Probe the problem may be in the Solid State Dual Level Control Board 3 If water starts flowing into the tank the Probe may be grounded due to e...

Страница 9: ...Water Boilers Cecilware 9 Parts Diagram...

Страница 10: ...10 Cecilware Water Boilers Wiring Diagram...

Страница 11: ...Water Boilers Cecilware 11 Wiring Diagram continued...

Страница 12: ...12 Cecilware Water Boilers Wiring Diagram continued...

Страница 13: ...tinued 1 PHASE 240 VOLTS G197A 2 x 3 5 KW TOTAL 7 KW 3 PHASE 240 VOLTS G197A 3 x 3 5 KW TOTAL 10 5 KW CONTACTOR CONTACTOR TERMINAL BLOCK L1 L2 N TERMINAL BLOCK L1 L2 L3 N SHEET 4 of 4 ELECTRICAL DIAGR...

Страница 14: ...14 Cecilware Water Boilers...

Страница 15: ...Water Boilers Cecilware 15...

Страница 16: ...lware 4003 Collins Lane Louisville KY 40245 USA Phone 502 425 4776 Toll Free 800 695 4500 Fax 502 425 4664 Web gmcw com Email info gmcw com 2016 Grindmaster Cecilware Printed in USA 0516 Form CW 328 0...

Отзывы: