background image

Water Boilers

Cecilware

®

5

Priming

NOTE: THERMOSTAT MUST BE IN THE "OFF"
POSITION.

1.  Open water supply line valve to boiler.
2. Turn on or plug in the power supply to the boiler.

The unit fills at the rate of 1 gallon (3.8 L) per minute.
Do not power up the boiler when the water line is off.

3.  When the water level becomes visible in the sight

gage, turn the thermostat clockwise to maximum
position. The unit will now automatically fill to
capacity and heat the water.

4. In high altitude locations (over 5000 ft. or 1500 m

above sea level), thermostat may have to be
lowered to prevent boiling. See the 

Adjustments

section if changes are needed.

5.  Heat and discard at least one batch of water. 

Cleaning

NOTICE:

All sanitizing agents in the food zone must

comply with 21 CFR 178.1010. Sanitize all food
dispensing units periodically. All parts to be sanitized
must be cleaned first. Cleaning and sanitizing frequency
must follow state and local health department
regulations.

NOTICE:

Do not use cleansers, bleach liquids,

powders, or any other substance containing chlorine.
These products promote corrosion and will pit the
stainless steel. USE OF THESE PRODUCTS WILL VOID THE
WARRANTY.

Daily

Wipe the outside of the unit with a damp cloth, using
soap solution or a non-abrasive compound when
required.

Sanitizing

1.  With power to the unit disconnected, fill unit to

capacity. 

2.  Prepare a sanitizing solution in accordance with

local health department regulations. You may also
refer to the US Food and Drug Administration
regulation 21 CFR 178.1010 “Sanitizing Solutions”
and US Environmental Protection Agency 40 CFR
18.940 “Tolerance exemptions for active and inert
ingredients for use in antimicrobial formulations
(Food-contact surface sanitizing solutions)”.

3.  Follow the instructions provided with the sanitizing

agent.

4. Drain all water from the unit slowly.
5. Let all sanitized parts drain and air dry. DO NOT

WIPE THEM DRY. 

6. If the unit is not to be used again immediately after

sanitizing - do not rinse with water. If the unit is to
be used immediately after sanitizing - rinse with
water before refilling the unit for further use.

CAUTION: BURN HAZARD

Water from boiler is very hot. Use caution when
pouring or transporting hot water. Accidental spills
may result in severe burns.

Faucet Body

Seat Cup

Bonnet

Faucet Handle

CAUTION: BURN HAZARD

Boiler surfaces and water inside boiler are very hot.
Use caution when cleaning unit to prevent burns.

CAUTION: BURN HAZARD

Never remove faucet when the liner has water in it.
Switch OFF the power to the unit at the circuit
breaker. Turn off the water line running to the boiler.

Содержание CME10E-N

Страница 1: ...9 Wiring Diagram 10 Thank you for purchasing this quality boiler For your safety and the safety of others read all warnings and the operator manual before installing or using the product Properly inst...

Страница 2: ...ock damage unit and will void warranty To reduce risk of explosion or fire do not use near combustibles WARNING Safety Information 2 Cecilware Water Boilers Important Safety Information This is the sa...

Страница 3: ...300 25 5 1 10 AWG 240 10 500 25 3 10 AWG 208 7 900 22 3 10 AWG NOTE 1 FIELD WIRING MUST BE SUITABLE FOR 75 DEGREES CELSIUS 2 USE COPPER WIRE ONLY FOR POWER SUPPLY CONNECTION 3 120 VOLT UNITS SUPPLIED...

Страница 4: ...ce such as a double check valve to be installed between the machine and the water supply Incoming pressure should be greater than 30 psi and not more than 70 psi NOTICE Connecting the water boiler to...

Страница 5: ...nit with a damp cloth using soap solution or a non abrasive compound when required Sanitizing 1 With power to the unit disconnected fill unit to capacity 2 Prepare a sanitizing solution in accordance...

Страница 6: ...stat shaft 2 Using a narrow bladed screwdriver engage slotted adjustment screw and turn it 1 4 turn slowly counter clockwise 3 Allow a few minutes for the temperature to reach set level The Heater Lig...

Страница 7: ...NOT TURN ON THERMOSTAT UNTIL BOILER IS PRIMED Replacing Thermostat Thermostat is located in side box of boiler Lift off side box door to gain access to thermostat then follow instructions below 1 Shut...

Страница 8: ...ll does not flow after the wire is disconnected from the Probe the problem may be in the Solid State Dual Level Control Board 3 If water starts flowing into the tank the Probe may be grounded due to e...

Страница 9: ...Water Boilers Cecilware 9 Parts Diagram...

Страница 10: ...10 Cecilware Water Boilers Wiring Diagram...

Страница 11: ...Water Boilers Cecilware 11 Wiring Diagram continued...

Страница 12: ...12 Cecilware Water Boilers Wiring Diagram continued...

Страница 13: ...tinued 1 PHASE 240 VOLTS G197A 2 x 3 5 KW TOTAL 7 KW 3 PHASE 240 VOLTS G197A 3 x 3 5 KW TOTAL 10 5 KW CONTACTOR CONTACTOR TERMINAL BLOCK L1 L2 N TERMINAL BLOCK L1 L2 L3 N SHEET 4 of 4 ELECTRICAL DIAGR...

Страница 14: ...14 Cecilware Water Boilers...

Страница 15: ...Water Boilers Cecilware 15...

Страница 16: ...lware 4003 Collins Lane Louisville KY 40245 USA Phone 502 425 4776 Toll Free 800 695 4500 Fax 502 425 4664 Web gmcw com Email info gmcw com 2016 Grindmaster Cecilware Printed in USA 0516 Form CW 328 0...

Отзывы: