For safe and proper operation, the appliance must be placed in a stable, vertical position. 

To reduce risk of serious burns or scalding do not place hand or other body parts under dispenser or container
while product is brewing.

Always unplug unit from power supply before servicing.

Surfaces are hot and can cause burns.

CAUTION

To reduce risk of electrical shock, do not remove or open cover. No user-serviceable parts inside. Repair should
be done by authorized service personnel only.

The appliance is not intended for outdoor use.

Do not clean with a water jet or use in an area where a water jet may be used.

Cleaning and maintenance shall be made only by properly trained persons with supervision.

This appliance is not intended for use by persons with reduced physical, sensory, or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

Do not alter or deform the power cord or plug in any way! Altering or deforming the plug may cause electrical
shock, damage unit and will void warranty.

To reduce risk of explosion or fire, do not use near combustibles.

WARNING

Safety Information

2

Cecilware

®

Water Boilers

Important Safety Information

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages
that follow this symbol to avoid possible injury or death.

For your safety and the safety of others, read all warnings and the operator manual before installing or using
the product. 

DANGER:

This term warns the user of imminent hazard that will result in serious injury or death.

WARNING:

This term refers to a potential hazard or unsafe practice, which could result in serious injury or death.

CAUTION:

This term refers to a potential hazard or unsafe practice, which could result in minor or moderate

injury.

NOTICE:

This term refers to information that needs special attention or must be fully understood. 

Use only on a circuit that is properly protected and capable of the rated load.

Electronically ground the chassis.

Follow national and local electrical codes.

Do not use extension cord. 

This equipment must be installed in compliance with applicable Federal, State and/or Local plumbing codes
having jurisdiction. This product requires an approved backflow prevention water device, such as a double check
valve, that must be installed between the machine and the water supply. 

NOTICE

Содержание CME10E-N

Страница 1: ...9 Wiring Diagram 10 Thank you for purchasing this quality boiler For your safety and the safety of others read all warnings and the operator manual before installing or using the product Properly inst...

Страница 2: ...ock damage unit and will void warranty To reduce risk of explosion or fire do not use near combustibles WARNING Safety Information 2 Cecilware Water Boilers Important Safety Information This is the sa...

Страница 3: ...300 25 5 1 10 AWG 240 10 500 25 3 10 AWG 208 7 900 22 3 10 AWG NOTE 1 FIELD WIRING MUST BE SUITABLE FOR 75 DEGREES CELSIUS 2 USE COPPER WIRE ONLY FOR POWER SUPPLY CONNECTION 3 120 VOLT UNITS SUPPLIED...

Страница 4: ...ce such as a double check valve to be installed between the machine and the water supply Incoming pressure should be greater than 30 psi and not more than 70 psi NOTICE Connecting the water boiler to...

Страница 5: ...nit with a damp cloth using soap solution or a non abrasive compound when required Sanitizing 1 With power to the unit disconnected fill unit to capacity 2 Prepare a sanitizing solution in accordance...

Страница 6: ...stat shaft 2 Using a narrow bladed screwdriver engage slotted adjustment screw and turn it 1 4 turn slowly counter clockwise 3 Allow a few minutes for the temperature to reach set level The Heater Lig...

Страница 7: ...NOT TURN ON THERMOSTAT UNTIL BOILER IS PRIMED Replacing Thermostat Thermostat is located in side box of boiler Lift off side box door to gain access to thermostat then follow instructions below 1 Shut...

Страница 8: ...ll does not flow after the wire is disconnected from the Probe the problem may be in the Solid State Dual Level Control Board 3 If water starts flowing into the tank the Probe may be grounded due to e...

Страница 9: ...Water Boilers Cecilware 9 Parts Diagram...

Страница 10: ...10 Cecilware Water Boilers Wiring Diagram...

Страница 11: ...Water Boilers Cecilware 11 Wiring Diagram continued...

Страница 12: ...12 Cecilware Water Boilers Wiring Diagram continued...

Страница 13: ...tinued 1 PHASE 240 VOLTS G197A 2 x 3 5 KW TOTAL 7 KW 3 PHASE 240 VOLTS G197A 3 x 3 5 KW TOTAL 10 5 KW CONTACTOR CONTACTOR TERMINAL BLOCK L1 L2 N TERMINAL BLOCK L1 L2 L3 N SHEET 4 of 4 ELECTRICAL DIAGR...

Страница 14: ...14 Cecilware Water Boilers...

Страница 15: ...Water Boilers Cecilware 15...

Страница 16: ...lware 4003 Collins Lane Louisville KY 40245 USA Phone 502 425 4776 Toll Free 800 695 4500 Fax 502 425 4664 Web gmcw com Email info gmcw com 2016 Grindmaster Cecilware Printed in USA 0516 Form CW 328 0...

Отзывы: