![Cebora CP-162C Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/cebora/cp-162c/cp-162c_instruction-manual_2577442011.webp)
11
• Reconnect connectors
A
and
B
, screw in the handle
M
and then the retention dowels
G1
and
G2
.
• Tighten the cable gland
F
.
5.6
REPLACING THE CABLE WITH CENTRAL
ADAPTER.
Fig. 10
AB
W
T
M
X
I1
Z
Y
Y1
N
K2
P
J
Remove spring
P
. Open the cover
W
by unscrewing the 4
set screws and then screw
M
. Remove pins of the control
cable
X
and
Z
. Take note of the position of each pin and
then remove the
U
-bolt
T
and the pins of the pilot arc red
cables
Y
and
Y1
. Cut the isolating hose
K2
and unscrew
body
N
from i tting
I1
. Assemble the new i tting and follow
the previous instructions in reverse direction. Use thread
sealer to lock the
N
body thread.
To avoid jeopardizing
the safety efi ciency, the body contacts N must be
connected as follows: pins Y and Y1 of pilot arc red
cables to contacts 5 and 6, pin X of cable J to contact
1, pin Z of cable J to contact 9.
Reconnect
U
-bolt
T
as described above.
5.7 WARNINGS
Periodically make sure that the welding torch cable is
intact and has no cuts or excessive wear. Replace it
immediately if needed.
Fig. 7
G1
G2
G1
M
F
Fig. 8
A
D
B
C