![Cebora 380 PW Скачать руководство пользователя страница 117](http://html1.mh-extra.com/html/cebora/380-pw/380-pw_instruction-manual_2577491117.webp)
117/164
3�7 Descripción conectores panel delantero (P)
Pin Descripción
Esquema de conexión
1
Start
digital input.
2
+ 5Vdc
voltage output for reference current external
potentiometer power supply.
3-6
Arc-ON
Relay contact (30Vdc 125Vac, 0,5A max).
arc lit = contact closed;
arc off = contact opened.
4
Down
Digital input performs the welding current set point
reduction.
5
n.c.
7
Gnd
0V for reference current external potentiometer power
supply
8
Up
digital input; performs the welding current set point
increasing
9
Gnd
0V for external commands
10
Current Ref
. analog input welding current set point signal
3�8 Descripción conectores panel trasero
Para los conectores CN1, CN2, CN3, CN4 remitirse al capítulo 13.4.
Conector Ethernet 100Mbit (LAN)
CN5
El conector es opcional, presente en caso de usarse el kit opcional
alimentación 24 Vdc para router Wifi periférico (Art. 45
1).
CN5
Pin
Descripción
1
+24Vdc 2A
2
0Vdc
Para más detalles, remitirse al manual de instrucciones del Kit Art. 451 cód.
3301068.
3�8�1
Interfaz equipo de refrigeración
La
sección correspondiente al equipo de refrigeración indicada en la figura 1 contiene:
M
Toma equipo de refrigeración
de tipo schuko, potencia máxima 230Vac 500W
N
Portafusible
fusible T 2A/230V – Ø 5x20 mm
O
Toma presóstato equipo de refrigeración
esta toma controla el presóstato del equipo de refrigeración y el
reconocimiento del equipo.
AVISO
La toma M se usa exclusivamente para conectar el equipo de refrigeración
GRV12 Art. 1683
al generador de
soldadura. La conexión de otros dispositivos puede afectar la integridad del generador de soldadura o comportar
anomalías de funcionamiento. CEBORA se exime de toda responsabilidad en caso de uso impropio del generador
y de los accesorios conectados al mismo.