![Cebora 380 PW Скачать руководство пользователя страница 107](http://html1.mh-extra.com/html/cebora/380-pw/380-pw_instruction-manual_2577491107.webp)
107/107
Code
Type
Error Description
Action
79
[W]
Combined with gas console Item 465.01
indicates that shielding gas pressure is high.
Check the pressure entering the shielding
channel. If the problem persists, contact
technical assistance.
81
[E]
Gas kit not present in combination with Kit Item
436.
Make sure that gas Kit Item 436 is correctly
connected. Switch the power source on and
off. If the problem persists, contact technical
assistance.
84
[W]
Quality control option error
Check the parameters set are correct.
86
[E]
Problems regulating the plasma gas flow.
Combined with gas console Item 465.01
Check there are no obstructions in the plasma
gas pipes.
Test the channel using the appropriate test
command. Check the cylinder inlet pressure,
because the desired flow cannot be regulated
if it is too low. If the problem persists, contact
technical assistance.
87
[E]
Problems regulating the shielding gas flow.
Combined with gas console Item 465.01.
Check there are no obstructions in the shielding
gas pipes.
Test the channel using the appropriate test
command. Check the cylinder inlet pressure,
because the desired flow cannot be regulated
if it is too low. If the problem persists, contact
technical assistance.
90
[W]
CNC not ready. In robotised applications with
connection to interface Items 448, 428.XX or
direct connection to CNC.
Check connection to power source CN2, check
the robot ready signal is present on the interface
or CNC. Check the accuracy of robot interface
parameters, check the interface and power
source terminal DIP switches. Turn off and
on. If the problem persists, contact technical
assistance.
95
[W]
Bluetooth mask not connected
Check the mask battery. Connect the mask to the
power source in accordance with the procedure
described in the relevant manual. If the problem
persists, contact technical assistance.
99
[E]
Machine is powering down.
Wait for the power source to power down. During
this stage, do not turn the power source back on
by turning the mains switch because the power
source would lock. Turn off the machine, wait for
at least 30 seconds and turn back on.