![CEA TREO 1800 Synergic MIG-MAG Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/cea/treo-1800-synergic-mig-mag/treo-1800-synergic-mig-mag_operators-manual_2577260034.webp)
12
3 - SPECIAL FUNCTIONS “Fx” SELECTION
The SPECIAL FUNCTIONS “Fx” that are only available in the MIG-
MAG manual welding process are shown below. For all the other
explanations regarding this menu make reference to the relative
paragraph.
■
FIRST LEVEL MENU
•
PRE GAS (PrG) -
Provides an additional quantity of gas for a
defined time, before welding starts.
•
STARTING SPEED (StS) -
Regulates the speed at which the
wire approaches the workpiece. The value indicated is a percen-
tage variation in relation to the factory setting value.
•
HOT START (HoT) -
Regulates the current intensity for igniting
the welding arc. The value indicated is a percentage variation
in relation to the factory setting value.
•
CRATER START SPEED (CSS) -
Sets the initial speed of the
welding wire for the crater.
•
CRATER START VOLTAGE (CSu) -
Sets the initial welding vol-
tage for the crater.
•
CRATER START TIME (CSt) -
This function defines the time
in which the current remains at the value of CRATER START
SPEED or CRATER START VOLTAGE.
•
SLOPE (SLo) -
Time necessary to pass from the level of CRA-
TER START SPEED or CRATER START VOLTAGE to the level
of welding current and to arrive from this level to the CRATER
END SPEED or CRATER END VOLTAGE level.
•
CRATER END SPEED (CES) -
Sets the final speed of the wel-
ding wire for the crater.
•
CRATER END VOLTAGE (CEu) -
Sets the final welding volta-
ge for the crater
•
CRATER END TIME (CEt) -
This function defines the time in
which the current remains at the value of CRATER END SPEED
or CRATER END VOLTAGE.
•
SPOT WELD TIME (SPt) -
The time during which spot welding
takes place after the arc is ignited, after which the arc is extin-
guished automatically.
•
STITCH WELD TIME (SAt) -
Time in which the welding in tracts
is performed after the ignition of the arch, after which the arch
switches off automatically.
•
STITCH WELD PAUSE (Srt) -
Time of pause between one wel-
ding in tracts and another.
•
BURN BACK (bub) -
Regulates the length of the wire after wel-
ding. The value indicated is a percentage variation in relation to
the factory setting value. Higher numbers correspond to more
burning of the wire.
•
POST GAS (PoG) -
Provides an additional quantity of gas for a
defined time, after welding ends.
Then there is an independent parameter,
SPECIAL FUNCTIONS
MENU (SPC FnC)
, that provides access to the SECOND LEVEL
MENU.
■
SECOND LEVEL MENU
See the “Special Functions Menu (SPC FnC)” paragraph.
4 - PRE-SETTING
Before welding it is possible to set the following parameters:
E1
T1
D1
WIRE SPEED
Example: WIRE SPEED
Press the PARAMETER SELECTION - A key (T1) until the LED
that corresponds to the WIRE SPEED switches on. Turn the EN-
CODER - A knob (E1) to change the value shown on the PARA-
METER DISPLAY - A screen (D1).
ADJUSTABLE FUNCTIONS “Fx”
FUNCTION
DISPLAY
SETTINGS RANGE
MIG-MAG WELDING MODE
FACTORY
RANGE
2T
4T
CRA 2T
CRA 4T
SPOT 2T
STITCH 2T
FIRST LEVEL MENU
MIG-MAG process
PRE GAS
PrG
0.1s
(0.0 ÷ 2.0)s
●
●
●
●
●
●
STARTING SPEED
Sts
0
-30 ÷ +30
●
●
●
●
●
●
HOT START
Hot
0
-30 ÷ +30
●
●
●
●
●
●
CRATER
INITIAL
CRATER
CRATER START SPEED
CSS
5.0m/min
(0.6 ÷ MAX)m/min
●
●
CRATER START VOLTAGE
CSu
15.0V
(min ÷ MAX)V
●
●
CRATER START TIME
CSt
1.0s
(0.0 ÷ 5.0)s
●
SLOPE
SLo
1.0s
(0.0 ÷ 8.0)s
●
●
FINAL
CRATER
CRATER END SPEED
CES
5.0m/min
(0.6 ÷ MAX)m/min
●
●
CRATER END VOLTAGE
CEu
15.0V
(min ÷ MAX)V
●
●
CRATER END TIME
CEt
0.0s
(0.0 ÷ 5.0)s
●
SPOT WELD TIME
SPt
3.0s
(0.1 ÷ 20.0)s
●
STITCH WELD
STITCH WELD TIME
SAt
1.0s
(0.1 ÷ 8.0)s
●
STITCH WELD PAUSE
Srt
1.0s
(0.1 ÷ 8.0)s
●
BURN BACK
bub
0
-30 ÷ +30
●
●
●
●
●
●
POST GAS
PoG
1.0s
(0.0 ÷ 10.0)s
●
●
●
●
●
●
SECOND LEVEL MENU
SPECIAL FUNCTIONS MENÙ
SPC FnC
PROCESS DEFAULT
dEF
no
no - YES
●
●
●
●
●
●
FACTORY DEFAULT
FAC
no
no - YES
●
●
●
●
●
●
SAFETY CALIBRATION CODE
SCC
7
0 ÷ 100
●
●
●
●
●
●
MOTOR CALIBRATION
CAL
●
●
●
●
●
●