4

DISPLAY AND LED INDICATIONS

 WELDING MODE 

SELECTION LED

 WELDING PROCESS 

SELECTION LED

 VRD LED

  HOLD FUNCTION LED

  PARAMETER DISPLAY screen - V

  PARAMETER DISPLAY screen - A

 PARAMETER 

SELECTION LED - V

 PARAMETER 

SELECTION LED - A

 MIG-MAG SYNERGIC 

PROCESS and 
PROGRAMME 
SELECTION LED

 

PARAMETER SELECTION LED - A

When one of these LEDs is on it means that the corresponding 

welding parameter has been selected.

 

MIG-MAG SYNERGIC PROCESS and PROGRAMME 

SELECTION LED

This LED will be lit only when the operator selects a welding pro-

cess (in which there welding programmes present) and the relati-

ve associated programme.

 

PARAMETER DISPLAY screen - A

This Display shows the values / numbers (set or measured) of the 

following parameters (if active):

•  THICKNESS OF WELDED ITEM (

).

•  WELDING CURRENT ( ).

•  WIRE SPEED (

).

•  WELDING PROGRAM (

).

 

HOLD FUNCTION LED

Flashing, it indicates that the values of the parameters views on 

the PARAMETER DISPLAY - A and V are respectively the values 

that are set or measured at the conclusion of the last welding. The 

LED flashes for 

15

 seconds consecutively before turning itself off 

or until the moment that the operator varies any parameter by me-

ans of the use of the handles.

 

WELDING PROCESS SELECTION LED

When one of these LEDs is on it means that the corresponding 

welding process has been selected.

 

PARAMETER SELECTION LED - V

When one of these LEDs is on it means that the corresponding 

welding parameter has been selected.

 

PARAMETER DISPLAY screen - V

This Display shows the values / numbers (set or measured) of the 

following parameters (if active):

•  ARC LENGTH ADJUSTMENT ( ).

•  WELDING VOLTAGE ( ).

•  ELECTRONIC INDUCTANCE (

).

 

VRD LED

The Voltage Reduction Device (VRD) is a safety device that redu-

ces voltage. It prevents voltages forming on the output terminals 

that may pose a danger to people.

Two-tone LED (off - red - green) indicates enabling of the VRD. In 

the welding process:

•  MIG MAG (Synergic and Manual) / JOB: the VRD device is not 

managed and therefore the LED always will be off.

•  MMA: the operator can decide whether or not to activate the 

VRD device (to activate the VRD device see the corresponding 

paragraph) based on its necessities and therefore the LED will 

be lit and will indicate the activation of the device.

•  TIG Lift: the VRD device is always inserted, independently from 

the state of the JUMPER and therefore the LED always will be lit.

 

WELDING MODE SELECTION LED

When one or a combination of these LED is lit, it means that the 

corresponding manner of welding has been selected.

  Switching on the welding

machine and initial screen

At the switching on of the welder (press the switch, located on the 

back panel, at the position I), the control performs a short opera-

tion of MACHINE CHECK (all of the LED light themselves simulta-

neously so as to verify their actual operation), and the panel display 

the INITIAL SCREEN (see the demonstrative figure), after which 

the operator can begin to work.

  Viewing the software version installed

1)  When the welding machine is working hold down the WEL-

DING PROCESS SELECTION key (T2) and WELDING MODE 

SELECTION key (T3) together for about 2 consecutive secon-

ds.

T2

T3

2)  On both displays appears a running string (see indicative 

example shown in Fig. A) that indicates the VERSION OF 

THE SOFTWARE installed on the welder where:

•  H04-11.00 indicates the version of HARDWARE installed.

•  F07-01.10 indicates the version of FIRMWARE installed.

•  C03-01.02 indicates the version of WELDING CURVES in-

stalled.

•  TrEo 1800 indicates the NAME of the welder.

Содержание TREO 1800 Synergic MIG-MAG

Страница 1: ...READ CAREFULLY 1020HA90B EN 12 2014 SN XN xxxxxx CEA COSTRUZIONI ELETTROMECCANICHE ANNETTONI S p A C so E Filiberto 27 23900 Lecco Italy Tel 39 0341 22322 Fax 39 0341 422646 Cas Post P O BOX 205 e ma...

Страница 2: ...knob for precise adjustment of the wire pressure that stays unvaried when the arms open and close Housing for coils of wire with max 200 mm 5 kg Possibility of fitting coils of wire up to max 300 mm...

Страница 3: ...d is exceeded a trip switch trips which protects the welding machine s internal components against dangerous overheat ing and prevents incorrect functioning of the machine for fur ther information see...

Страница 4: ...s hearing aids and similar equipment must consult their doctor before going near a ma chine in operation The equipment s installation environment must comply to the protection level of the frame i e I...

Страница 5: ...e mechanism Pos 6 Fig B Check that the drive roller Pos 4 Fig B has the diameter corresponding to the wire being used printed on the outer side Thread the wire into the central wire guide and into the...

Страница 6: ...hange polarity cable is connected to the positive pole 2 Welding 1 Open the moving cover and fit the coil of wire 2 Load the wire see the Loading the wire paragraph 3 Switch the welding machine on by...

Страница 7: ...torch Remove the gas guide and wire guide nozzles allowing the wire to flow freely during loading Remember that the contact tip must correspond to the wire diameter Push the torch push button or the...

Страница 8: ...reduce tungsten inclusions on ignition to a mini mum The molten bath and the electrode are protected by and inert gas for example Argon This type of welding is used to weld thin sheet metal or when el...

Страница 9: ...nly For a precise choice follow the instructions provided by the electrode manufacturer Table 4 WELDING THICKNESS mm ELECTRODE mm 1 2 2 1 5 3 3 5 5 12 1 6 2 2 5 3 2 The current to be used depends on t...

Страница 10: ...y connected to the plug and the supply switch 3 Check that the power fuses are not burned out or loose 4 Check whether the following are defective The switch that supplies the machine The plug socket...

Страница 11: ...ring that powers the various boards Check and if necessary replace the digital interface PCB or the control PCB No gas coming out of the torch Check and if necessary replace the solenoid valve or gas...

Страница 12: ...12 Electro topographical diagram 2101AB10...

Страница 13: ...B 17 Hall effect transformer 18 MMA torch 19 TIG torch 20 MIG MAG torch 21 Main transformer 22 Second ary diodes thermostat Colour key Ar Orange Az Sky Blue Bc White Bl Blue Gg Grey Gl Yellow GV Yello...

Страница 14: ......

Страница 15: ...ERE ATTENTAMENTE EN Spare parts list READ CAREFULLY CEA COSTRUZIONI ELETTROMECCANICHE ANNETTONI S p A C so E Filiberto 27 23900 Lecco Italy Tel 39 0341 22322 Fax 39 0341 422646 Cas Post P O BOX 205 e...

Страница 16: ...dex 4 352415 Pannello frontale Front panel 5 468185 Adesivo dinse Dinse sticker 6 403611 Attacco rapido Quick connection 7 239624 Cavo massa Ground cable 8 428110 Flangia Flange 9 434250 Tubetto guida...

Страница 17: ...ia Fixing bracket handle 17 435364 Interruttore alimentazione Mains switch 18 427895 Pressacavo completo di ghiera Cable clamp with lock ring 19 235960 Cavo alimentazione Mains cable 20 427866 Pressac...

Страница 18: ...bio polarit Change polarity protection box 23 240561 Meccanismo di trascinamento con motoriduttore Wire feed mechanism with motorgear 24 404913 Telaio metallico interno Internal metallic chassis 25 24...

Страница 19: ...Tubo gas Gas tube 32 353448 Isolamento laterale coperchio Cover insulation 33 486386 Motore ventilatore Fan motor 34 241266 Complessivo inverter di potenza Power inverter assembly 35 481954 Trasformat...

Страница 20: ...e arm 6 422923 Rullo di pressione 26 mm Feed roll 26 mm 7 487808 Vite di fissaggio M4x8 M4x8 Fixing screw 8 356956 Leva di pressione completa Complete pressure arm 9 676510 Spina elastica Pin pressure...

Страница 21: ...ei pezzi di ricambio Per la richiesta di pezzi di ricambio indicare chiaramente 1 Il numero di codice del particolare 2 Il tipo di impianto 3 La tensione e la frequenza che rileverete dalla targhetta...

Страница 22: ......

Страница 23: ...or s manual READ CAREFULLY CEA COSTRUZIONI ELETTROMECCANICHE ANNETTONI S p A C so E Filiberto 27 23900 Lecco Italy Tel 39 0341 22322 Fax 39 0341 422646 Cas Post P O BOX 205 e mail cea ceaweld com web...

Страница 24: ...N 11 2 WELDING MODE SELECTION 11 3 SPECIAL FUNCTIONS Fx SELECTION 12 4 PRE SETTING 12 5 WELDING 13 6 HOLD 13 Introduction This manual describes the functions and the manner of utilisation of the TX 18...

Страница 25: ...2T 2T LED switched on Pressing the TORCH TRIGGER starts the welding cycle which will stop when it is released FOUR STROKE 4T 4T LED switched on 1 Pressing and releasing the TORCH TRIGGER will start t...

Страница 26: ...ction Device VRD is a safety device that redu ces voltage It prevents voltages forming on the output terminals that may pose a danger to people Two tone LED off red green indicates enabling of the VRD...

Страница 27: ...ns the parameters normally used for set process functionality described in specific para graphs Then there is an independent parameter SPECIAL FUNCTIONS MENU SPC FnC that provides access to the SECOND...

Страница 28: ...MIG MAG SYN MIG MAG MAN TIG MMA 2T 4T CRA 2T CRA 4T SPOT 2T STITCH 2T FIRST LEVEL MENU MIG MAG process PRE GAS PrG 0 1s 0 0 2 0 s STARTING SPEED Sts 0 30 30 HOT START Hot 0 30 30 CRATER INITIAL CRATE...

Страница 29: ...T2 7 V 4 At this stage the partial reset or process default procedure has been completed successfully the parameters have been taken back to the factory values while any JOBS saved re main unaltered...

Страница 30: ...e seconds T2 7 V The procedure of calibration is carried out in 3 different phases 1 Calibration parameter SM1 MINIMUM SPEED Press and release the torch button then wait for the auto matic arrest of t...

Страница 31: ...2 MiG 010 011 Fe G3 Si 1 0 8 Ar 16 20 CO2 MiG 011 012 Fe G3 Si 1 1 0 Ar 16 20 CO2 MiG 012 015 Fe G3 Si 1 0 9 Ar 16 20 CO2 MiG 015 195 Fe rutil flux cored E71T GS 0 9 MiG 195 231 CrNi 308 G 19 9 LSI 0...

Страница 32: ...BURN BACK bub Regulates the length of the wire after wel ding The value indicated is a percentage variation in relation to the factory setting value Higher numbers correspond to more burning of the wi...

Страница 33: ...LED for a specific amount of time Once the welding has been terminated for about 15 seconds both the DISPLAYS should show the same values of the parameters during the welding In this phase the display...

Страница 34: ...ing in tracts is performed after the ignition of the arch after which the arch switches off automatically STITCH WELD PAUSE Srt Time of pause between one wel ding in tracts and another BURN BACK bub R...

Страница 35: ...for a specific amount of time Once the welding has been terminated for about 15 seconds both the DISPLAYS should show the same values of the parameters during the welding In this phase the displays s...

Страница 36: ...f low function at the start of the connection ARC FORCE ArC During the welding process it increases the current in percentage reducing in such a way the risk of fu sing the electrode to the piece Then...

Страница 37: ...ding Once 15 seconds have passed HOLD FUNCTION the TX con trol panel goes back to the PRESETTING phase 7 ACTIVATING THE VRD DEVICE The Voltage Reduction Device VRD is a safety device that redu ces vol...

Страница 38: ...L FUNCTIONS MENU SPC FnC that provides access to the SECOND LEVEL MENU SECOND LEVEL MENU See the Special Functions Menu SPC FnC paragraph 3 PRE SETTING Before welding it is possible to set the followi...

Страница 39: ...T2 To be able to choose another automatic welding point JOB that is free for saving the data simply turn one of the two EN CODER E1 E2 knobs until you reach the required point E1 E2 WARNING If all th...

Страница 40: ...its settings in the wel ding process it comes from keeping the SAVE MEM key T2 pressed for a duration of about 3 seconds 4 Acquire the parameters necessary for editing the JOB 5 Hold the SAVE MEM key...

Страница 41: ...istance dept Err E4 2 MIG SYN SPECIAL FUNCTION Fx WRONG NON automatic reset error Immediately contact technical assistance dept Err E4 3 MIG MAN SPECIAL FUNCTION Fx WRONG NON automatic reset error Imm...

Страница 42: ......