1] GENERAL INFORMATION
Output formats:
- Wiegand,
- Standard format,
- ISO Track 2 format.
Back-lighted.
Rear switch on the GALEOW for entry to
and exit from programming mode.
Permanent E2PROM memory back-up.
Number of digits: 4, 5 or 6.
Operating voltage: 12 V DC.
Consumption: 100 mA max.
3] MOUNTING KIT
2] NOTES AND RECOMMENDATIONS
Wiring reminder
- In the case of direct connection to the CTV900A
(CENTAUR) central controller or AC22 (ATRIUM)
door controllers, the GALEOW must be
installed within a maximum distance of 50 m.
- In other cases, the distance between the GALEOW
and the (INTBUSW) door controller must be within a
maximum of 50 m and the distance between the
central controller or panel and the last (INTBUSW door
controller may be up to 1200 m maximum.
- Take care not to pass your wires close
to «High voltage» cables (e.g.: 230 V AC).
Recommended cables
2 pairs of cables (4 strand) SYT1 8/10ths (Shielded
cables - AWG 20).
Fitting
To optimise the mounting of the GALEOW and to combat
attempted tampering, it should be fi tted on a fl at surface.
Recommended power supplies
- A power supply independent of the central controller
is necessary for the GALEOW.
- There are two suitable power supplies for this
Digicode
®
keypad: ARD12 or BS60
Installation recommendations
To protect the installation, remember to:
- install the varistor in parallel on the locking
system power supply side,
- install a 120 ohm resistor between A and B
on the last BUS RS485 door controller.
IP64
-25°C to +70°C
CE Certifi cation
Envrionmental tests:
vibrations
WEEE & RoHS
HIGH RESISTANCE
TO VANDALISM
Varistor
GALEOW
1
1
1
2
2
2
Torx
®
screw
(M4x10)
T20 Torx
®
spanner
Cap
mounting
screw
(M4x30)
S5 plastic
anchor
4] MOUNTING
After having verifi ed that the fi tting kit is complete and having made the connection of the GALEOW coded
keypad (with or without the door controller depending on whether you use a central controller or panel), you
can proceed with the fi nal installation of the product. Collect up the necessary tools (drill, screwdriver, measuring
tape, etc) and follow the GALEOW fi tting instructions:
5] CONNECTIONS:
DIRECT CONNECTION TO THE TERMINAL BLOCKS OF A CONTROLLER
Controller terminal wirings
GALEOW
Outputs
CTV900A
(CENTAUR)
AC22
(ATRIUM)
UCA3
PROMI1000
PROMI1000PC
PROMI500
DGPROX
DG502
RED
Input voltage
12VDC
+12V
+12V
BLACK
0V
R2/0V
GND
BROWN
Buzzer command
input
OUT5/6
BUZ
GREEN
DATA 0
R2/D0
D0
WHITE
DATA 1
R2/D1
D1
BLUE
CLOCK
6 and 10
1
1
1
1 and 6
GREY
0V COMMON
5 and 9
M
M
M
4
EN
GALEOW
Illuminated keypad - Wiegand
GALEOW
Illuminated keypad - Wiegand
INSTALLATION MANUAL
INSTALLATION MANUAL
EXE-CDVI_IM GALEOW CMYK A5 EN-FR 07.indd 12