EN
EN
DIGIWAY Plus
Inward or Outward Door Operator
32
FMoOcCBXbsMiIUJ
P=-000.0 V=-00.0
LEGEND
LEGEND DISPLAY EXPERT MODE
DISPLAY EXPERT MODE
M / S
M / S
o
o
O
O
cc
C
C
B
B
1,2,3,4,5,f
1,2,3,4,5,f
b
b
ss
M
M
ii
II
U
U
J/E
J/E
Master /
Master /
Slave
Slave
Opening
Opening Open
Open Closing
Closing Closed
Closed Obstacle
Obstacle
Obstacle
Obstacle
type
type
restart for
restart for
obstacle
obstacle
Stop
Stop Motor
Motor Opening
Opening
current
current
Closing
Closing
current
current Electrolock
Electrolock Opening
Opening
Jolt
Jolt
Position (+/-)
Position (+/-)
Speed: rpm/10
Speed: rpm/10
P
P
V
V
Factory Defaults
Factory Defaults
If the setup of the parameters hasn’t been successful, you can recover the factory
If the setup of the parameters hasn’t been successful, you can recover the factory
settings using the sub-menu FACTORY DEFAULTS from the Main Menu. After the
settings using the sub-menu FACTORY DEFAULTS from the Main Menu. After the
completion of this function, all the parameters will be reset to factory values. See each
completion of this function, all the parameters will be reset to factory values. See each
function to find the corresponding value.
function to find the corresponding value.
Menu Main
Factory Defaults
Reset to Factory
Defaults?
Are you sure?
Having reset the system to the factory settings, the engineer can operate the door but
Having reset the system to the factory settings, the engineer can operate the door but
without using the acceleration and deceleration values calculated during the Step III
without using the acceleration and deceleration values calculated during the Step III
of Door Calibration. In order to revert to the previous operating mode it is necessary
of Door Calibration. In order to revert to the previous operating mode it is necessary
to repeat Step III again. The door limits (DOOR CLOSE and DOOR OPEN) remain the
to repeat Step III again. The door limits (DOOR CLOSE and DOOR OPEN) remain the
same. The transmitter memory is completely erased, Master transmitter included, and
same. The transmitter memory is completely erased, Master transmitter included, and
the System password for the partial counter is reset to 1111.
the System password for the partial counter is reset to 1111.
System Reset
System Reset
It is possible to reset the system, equivalent to a “power-off + poweron”, using the
It is possible to reset the system, equivalent to a “power-off + poweron”, using the
option “System Reset” from the Main Menu. After the system reset the LCD displays the
option “System Reset” from the Main Menu. After the system reset the LCD displays the
SW release, the condition of the parameters condition and the free memory space for
SW release, the condition of the parameters condition and the free memory space for
transmitters. This function doesn’t change the value of any parameter except for the
transmitters. This function doesn’t change the value of any parameter except for the
currents (I and i) which will be re-calculated during the next 2 cycles.
currents (I and i) which will be re-calculated during the next 2 cycles.
Answer OK to proceed or ESC to exit without any action
Answer OK to proceed or ESC to exit without any action
MENU MAIN
System Reset
Are you sure?
Confirm
System Reset?
Action in progress
Action in progress
FF
Forward
Forward
R
R
Reverse
Reverse
K
K
Brake
Brake
II
Idle
Idle