45
ElECTRICAl FEEDER CABlE
CONNECTION
WARNING: The power supply cable must be connected only by an authorised service agent
in order to avoid a hazard.
To connect the feeder cable to the cooker it is necessary to:
•
Remove the 2 screws that hold shield “
A
” behind the cooker.
•
Open completely the cable clamp “
D
”.
•
Insert the feeder cable into the cable save “
P
”. The supply cable must be of a suitable size for
the current requirements of the appliance; see the section “Feeder cable section”.
•
Connect the live, neutral and earth cables to terminal “
B
” according to figures 42 and 43.
•
Pull the feeder cable and block it with the cable clamp “
D
”.
•
Re-mount shield “
A
”.
Note: The earth conductor must be left about 3 cm longer than the others.
FEEDER CABlE SECTION
TYPE h05RRF
230 V~ 3 x 2.5 mm
2
(*) Connection with wall box connection
230 V
PE
N
L
1
(L
2
)
PE Earth
N
Neutral
L
Live
P
D
B
A
Fig. 43
Fig. 42