44
REVEX
1PH from 30A to 40A
User’s manual
10.6 Software General information
Here it is described the Confi gurator Software and how to use it.
10.6.1 Program Window
Main Menu
Access these menus.
File menu
Exit
: close the program
Setting menu
Language
: open Language Settings dialog
box
Serial Port
: open Serial Port dialog box
Option
: open General Option dialog box
? (Help) menu
Message Log
: open a serial
communication message view
About
: displays the About dialog with the
program name and version and contact
information
Instruments selector
Select the right instrument to use:
HOME
: the default view
REVEX 1PH
: open the Simple and Test views for a single-phase power controller
REVEX 2/3PH
: access the Simple and Test views for a two-phase or three-phase power controller
MSG
: opens a serial communication message view
Status Bar
Indicates information such as time and date, communications port and baud rate.
10.6.2 Simple Section
This section is used to create, save, upload and download
recipes of parameters settings. Can be used also to see
the settings in a controller.
Simple page is the default page when select the model
using the Model Button, but if not selected is possible to
access it by clicking the Simple tab below the main menu.
NOTE!
This section is not “OnLine”
so the
parameter values are not updated continuously.
They are read only when you upload them from the
power controller.
To manage a recipe click on:
Create a New recipe
: create a recipe fi le with the
standard default settings
Open existing recipe
: open an existing recipe fi le
Upload from unit
: create a new recipe with the value
uploaded from a connected power controller
Close
: close the current recipe
Save
: save the recipe in a fi le
Save as
: save a copy of the recipe in a fi le
Download to unit
: send the current recipe parameters in the connected
power controller
: print the recipe (see sample at right)
Print report
: print the recipe (see sample at right)
To edit the actual recipe values click a parameter menu name:
SETUP
ADVANCED SETUP
HARDWARE
COMMUNICATIONS
and after click on the value and modify it.
NOTE!
Changes to the values here aff ect
the open recipe only. To apply these
changes to the power controller settings,
download them to the power controller
using the Download to unit option.
10.6.3 Test Section
This section is used to monitor and adjust the
operation of the power controller in real time
using RS485 or USB communication port.
After select the model, is possible access to
this section clicking the “TEST” tab below the
main menu.
Operating on TEST Section:
Online
button: is the button to start or stop
communication updates with the power
controller.
After communication starts, a green
communication status indicator spins
clockwise when the software communicates
correctly with a power controller, if the connection link is broken the color will become red
Address
: value used to set the power controller address
Access Level:
click the value to log in or out. Default Password address is “1111”.