![CCTV PTA1318X Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/cctv/pta1318x/pta1318x_user-manual_2575913020.webp)
CCTV SYSTEM
20
10.Other System Settings
MAIN MENU
<SYSTEM SETTINGS>
< CAMERA SETTINGS>
<DISPLAY SETTINGS>
< DOME SETTINGS>
< RUN SETTINGS>
<SYSTEM INFORMA TION>
.EXIT
SYSTEM INFO
Language: Chinese/English
Output Format: PAL/NTSC
Pan Display Position:49<0-63>
Tilt Display Position:31<0-31>
<Date and Time>
<Password>
<Communication>
<Others
>
<Restore Factory Settings>
RETURN EXIT
OTHER SETTINGS
Dome Temperature:29
°
Fan open temperature:50
°
Fan IR switch: ON/ OFF
Auxiliary
;
ON/OFF
Menu Save Time:030
Save
RETURN EXIT
1.Pan start Temperature
Users can defined the pan start temperature by menu, the de-
fined temperature is 45
°
Setting method: Move the cursor to
“
Fan open tempera-
ture
”,
the joysticks turn right to options, up and down the joy-
sticks to increase or decrease the number, also can press[ FAR ]
OR [ NEAR] . Turn the joystick right and left or press [ OPEN/
IRIS ON] confirmation and input,
press [CLOSE/ IRIS OFF]
cancel input.
2. Save the menu time
When nobody operate the speed dome and the speed dome
menu is opening . User can choose 1-254 second to set to
keep display for a period time .
3.Save settings
All the modify settings need save. Up and down the cursor
to <SAVE>, Turn joystick right or press [OPEN/ IRIS ON]
save and modify
IR Intelligent Speed Dome Operation Manual ver2.0
25
16.Alarm Settings
MAIN MENU
<SYSTEM SETTINGS>
<CAMERA SETTINGS>
< DISPLAY SETTINGS>
<DOME SETTINGS>
<RUN SETTINGS>
< SYSTEM INFORMATION>
EXIT
DOME SETTINGS
Dome title:DOME0001
Boot action: 000
Free action: 001
Free time :005
<IR settings>
< Aram settings>
< Privacy masking>
< Others>
SAVE EXIT
ARAM SETTINGS
No.< 1-4 >: 4
Display instructions :ON
Preset : 001
Retention time: 005
Start: close
Save
RRTURN EXIT
The speed dome can support 4 channel alarm input,1 channel
output, realize alarm linkage.
1.Alarm number setting
Move cursor to [ NO.] , then turn joystick right, the setting area
display shine situation. Up and down joystick to set alarm no.,
joystick turn right or left to save or press[ OPEN/ IRIS ON
]
save
modify.
2. Alarm display switch
Move cursor to [Display instructions], then turn joystick
right ,the setting area display shine situation. Up and down the
joystick to open and close in the alarm settings.
3.Alarm linkage setting
Move cursor to [preset No./preset ],Then turn joystick right ,the
setting area display shine situation, Up and down the joystick to set
alarm linkage . The linkage action can be selected between 1-255
operational function can be executed. Close to 000 presser. Then
turn joystick right or left to modify save or press [OPEN / IRIS
ON]
4.Retenrion time
Move cursor to [ Time/ save time], then turn joystick right ,the
setting area display shine situation, up and down to set the time of
alarm retention.
5.Alarm open & close
Move cursor to [ Enable/ start], then turn joystick right ,the
setting area display shine situation, up and down to set the alarm
number open and close .
6.Save times
Finish input, move cursor to,< save>, turn joystick right or
[OPRN/ IRIS ON], save modify.
7.Return or Exit
If not save, move cursor to “ Return or Exit
”,
turn joystick
right or press[ OPEN/IRIS OPEN], Cancel modify and return the
level menu or exit menu.