CCTV PTA1318X Скачать руководство пользователя страница 18

                                                                                                   CCTV SYSTEM 

18 

8.Menu Password Protection Settings 

MAIN MENU 

      
    <SYSTEM SETTINGS> 
    <CAMERA SETTINGS> 
     <DISPLAY SETTINGS> 
    < DOME SETTINGS> 
     <RUN SETTINGS> 
    <SYSTEM INFORMA   TION> 
     
 
    .EXIT 

           

SYSTEM INFO

 

 
    Language: Chinese/English 
    Output Format: PAL/NTSC 
    Pan Display Position:49<0-63> 
    Tilt Display Position:31<0-31> 
    <Date and Time> 
    <Password> 
    <Communication> 
    <Others

    <Restore Factory Settings> 

     
     RETURN                  EXIT                

             

Password 

   
         
     New password:***** 
     Start: ON/OFF 
     Save 
      
 
   RETURN                EXIT

 

 

There   is   no   limit   permissions   set   to   modify   the   speed 

dome    system,  the  password  can  protect  the  speed  dome.  When  open 
the  speed  dome ,  the users  need input the  password. Modify  the pass-
word as follows: 
 
  1.Password switch 
 

   Move  the  cursor  to 

start”,  turn  joystick  right  to  choose  password 

open  or  close.  When the  password  protection is open ,  you  need input 
password. 
 
  2.Modify the password 
 

   Move  the  cursor  to 

new

 

password

”, 

turn  the  joystick  right  to 

choose  input  position,  when    the 

input  position  turn  to  spark  state, 

the  joystick    up  and  down  to  increase  and  decrease    the  number. 
Turn the joystick left and right or press[ OPEN/ IRIS ON] confir-
mation and input, press [CLOSE/ IRIS OFF] cancel input. 
 
    Speed dome boot password is 000000 
 
     Up  and  down  the  cursor  to  <SAVE>,  Turn  joystick  right  or 
press [OPEN/ IRIS ON] save and modify

 

 
 

 

IR Intelligent Speed Dome Operation Manual                                          ver2.0 

27 

 

18.Preset settings

 

   MAIN MENU 

 
     <SYSTEM SETTINGS> 
     <CAMERA SETTINGS> 
     <DISPLAY SETTINGS> 
     <DOME SETTINGS> 
     <RUN SETTINGS> 
    <  SYSTEM  INFORMATION> 
     
      
    EXIT 

          RUN SETTINGS 
 
     

< Preset> 

     < Tour> 
     < Limit scan> 
     <Pattern scan> 
     < Zone> 
     < Timing> 
     < Auto-tracking

 
 

    Return                       EXIT

 

              PRESET 
 
     NO.<1-90:151-254.:001

 

     Title: POS001 
     Position 
     Clear 
     Save

 

    
   

RETURN          EXIT

 

    1 .set the preset position number 

    Move the  cursor to  "number", or press  [OPEN/IRIS  ON  ]go   into 
the preset number mode. Joystick up and down to set preset number. 
The  dome  support  195  PCS  preset,  1-90,151-255,then  turn  joystick 
right or press [ OPEN/IRIS ON] and confirmation. 
 
  2.Set preset title 
   Move  cursor  to  “  title”  ,  turn  joystick  right  or  press  [OPEN/  IRIS 
ON]   go  into  preset   title   settings,  

Preset   title   up   to  8  charac-

ters

 .,support characters (0-9,A-Z, space) . Finished title setting, then 

joystick turn right or left to confirm or press[ OPEN/IRIS ON confir-
mation. 
 
   3.Call preset 
    Move  cursor  to  “  Call  “,  Press  the  aperture  open  will  call  the 
corresponding preset number of preset scenarios.  
 
   4.Preset position setting 
    Move  cursor  to  “  position”  ,  turn  joystick  right  or  press  [  OPEN/
IRIS ON] go into preset setting mode, now the user can operate with 
the  seed  dome  .Reach  the    desired  preset  ,  then  pres  [  OPEN/  IRIS 
ON, confirm to save the present  position. 
 
  5.Clear preset  scene 
   Move cursor to “ clear “ , joystick turn right or press [ OPEN/ IRIS 
ON] ,delete corresponding preset number in preset scene. 
 
  6. After these settings, move the cursor to <save ,turn joystick right 
or [ OPEN/IRIS ON], save modify. 
 
   7.if  want  delete  the  zone  number  of  privacy  protection,  move  the  
cursor to [ clear], then  turn joystick right and delete.

 

Содержание PTA1318X

Страница 1: ...eration maintenance or other accidental situations The distribution and marketing must be conducted by the original purchaser un der the items of permission agreement No company or individual is allow...

Страница 2: ...me 12 6 Product Connection 12 Part 7 Menu Setting of OSD System 13 1 English Menu Index 13 2 Basic Operation 14 3 Power on and Self check 15 4 Main Menu Description 15 5 Restore Factory Settings 16 6...

Страница 3: ...1 215 1 1 1 0 1 0 1 1 246 0 1 1 0 1 1 1 1 216 0 0 0 1 1 0 1 1 247 1 1 1 0 1 1 1 1 217 1 0 0 1 1 0 1 1 248 0 0 0 1 1 1 1 1 218 0 1 0 1 1 0 1 1 249 1 0 0 1 1 1 1 1 219 1 1 0 1 1 0 1 1 250 0 1 0 1 1 1 1...

Страница 4: ...SAMSUNG LG CNB CANON etc and some domestic zoom cameras Other zoom cameras should provide their protocols 2 Built in Decoder PAN TILT Adopt the ARM design of high performance with high stable stabilit...

Страница 5: ...256 preset positions 5 automatic programmable cruising function which can store 16 presets including guarding point cruising group 4 tracking record 8privacy protecting area and 8 area indication etc...

Страница 6: ...get a panorama or close up pictures by controlling the keyboard to adjust focal length b Focus control Auto focus is included in system default When zooming camera will focus in the center of picture...

Страница 7: ...37ft 18m 60ft 28m 95ft 45m 152ft Model Max transmitting distance 75 5 370M 75 7 500M 75 9 680M Model Max transmitting distance 75 2 150M 75 3 200M 75 4 270M IR Intelligent Speed Dome Operation Manual...

Страница 8: ...er in the center of installation place On one side of the hole twist a self drilling screw and fix it on the ceiling 2 Draw a circle with pencil in ceiling and then remove the material inside the circ...

Страница 9: ...each speed dome camera Control lines reversed or open circuit Check the wiring of control lines to ensure that wiring is correct and good contact The address or protocol baud rate of the speed dome ca...

Страница 10: ...nstallation Insert the three setscrews which are in the bottom of dome into the holes in the ceiling mount and then turn the mount as figure 9 shows to make sure that the screws are inside position in...

Страница 11: ...n off the speed dome of camera initialization IR Intelligent Speed Dome Operation Manual ver2 0 11 Step c Set speed dome 1 Set DIP switches SW2 under the bottom of dome machine to control speed dome I...

Страница 12: ...t scan 112 Save the limit scan 110 Set the left and right limit scanning speed call No 110 preset call preset N N for 1 100 representing the speed grade the default of 10 de grees per second 115 Start...

Страница 13: ...VER POS 44 0 31 DATE TIME PASSWORD COMMUNICATION OTHER FACTORY RESET RETURN EXIT PRESET POS SETTINGS NO 1 90 151 254 001 TITLE POS001 P T POS CLEAR SAVE RETURN EXIT DATE TIME DATE 2013 05 22 TIME 19...

Страница 14: ...er control rocker control ball machine rotates to the region a preset range the screen display area title set in different regions conven ient user identification in the field of view Setting method a...

Страница 15: ...or it will end of pattern scan setting 5 Delete pattern scan route Move cursor to clear turn joystick right or OPEN IRIS ON it will delete the pattern scan route 6 Save After these settings move the...

Страница 16: ...Settings IR Intelligent Speed Dome Operation Manual ver2 0 29 20 Limit Scan Settings RUN SETTINGS Preset Tour Limit scan Pattern scan Zone Timing Auto tracking Return EXIT MAIN MENU SYSTEM SETTINGS CA...

Страница 17: ...bottom through each preset rotation If the preset point of 0 will automati cally jump to the next that is not 0 preset and rotation 4 After these settings move the cursor to save turn joystick right...

Страница 18: ...INGS CAMERA SETTINGS DISPLAY SETTINGS DOME SETTINGS RUN SETTINGS SYSTEM INFORMATION EXIT RUN SETTINGS Preset Tour Limit scan Pattern scan Zone Timing Auto tracking Return EXIT PRESET NO 1 90 151 254 0...

Страница 19: ...adjust privacy protection block width move the joystick to adjust privacy protection block height Note press rocker is not put about 2 seconds later privacy protection block width or height with rock...

Страница 20: ...000 Free action 001 Free time 005 IR settings Aram settings Privacy masking Others SAVE EXIT ARAM SETTINGS No 1 4 4 Display instructions ON Preset 001 Retention time 005 Start close Save RRTURN EXIT...

Страница 21: ...of 10 level change 00 is close 10 is maximum brightness IR Intelligent Speed Dome Operation Manual ver2 0 21 11 Camera Settings MAIN MENU SYSTEM SETTINGS CAMERA SETTINGS DISPLAY SETTINGS DOME SETTING...

Страница 22: ...INFORMATION EXIT DOME SETTINGS Dome title DOME0001 Boot action 000 Free action 001 Free time 005 IR settings Aram settings Privacy masking Others SAVE EXIT MAIN MENU YSTEM SETTINGS AMERA SETTINGS ISP...

Отзывы: