background image

CCEI 

Limpido EZ

®

  

Duo

 

v1.0 

 

Page 9 

LOW TEMPERATURE AND TEMPERATURE FAULT 

In  the 

Automatic  mode

  (thermoregulated),  the  device  stops  producing  when  the 

temperature is less than 10°C. The thermoregulated indicator light intermittently turns on 
(1 periodic flash). 
When  the  temperature  rises  above  11°C, 

Limpido  EZ

®

 Duo

  automatically  resumes  the 

treatment. 
In  case  the  device  detects  a  temperature  measurement  fault, 

Limpido  EZ

®

  Duo

 

switches to the 

Permanent mode (Shock)

 
When  the  daily  filtration  duration  is  insufficient  to  allow  producing  the  necessary  time  (

Automatic 

mode), 

Limpido EZ

®

 Duo

 actuates a contact to force the running of the filtration pump (cf § Forced 

filtration) and indicates its state by 5 periodic flashes of the 

thermoregulated 

indicator light. 

 

Thermoregulation 

indicator light 

Description of the state 

Unlit 

Shock mode 

Lit 

Thermoregulated automatic mode 

1 periodic flash 

Water temperature too low to produce (<10°C) 

5 periodic flashes 

Filtration insufficient / Forced filtration 

Permanently flashing  

Temperature measurement error 

 

POLARITY INDICATOR 

The cell is cleaned by a periodic polarity reversal. 
Two  indicator  lights  indicate  the  production  polarity.  To  preserve  the  service  life  of  the 
cell’s  electrodes,  a  pause  of  several  minutes  separates  the  changing  of  polarity.  During  
this pause, both polarity indicator lights alternately flash. 
 
 

 

PRODUCTION INDICATOR 

The production indicator allows checking the production level. 
 

The production level is given by green and yellow indicator lights.  
If  no  green  indicator  light  is  lit  despite  a  production  set  to  the 
maximum, then it is necessary to check the salt ratio. 
If the yellow Low production indicator light and at least one of the 
three  green  indicator  lights  are  lit,  it  means  that  the  production 
level is optimum. 
 
 

Limpido  EZ

®

  Duo

  is  equipped  with  a  protection  device  which 

stops production as soon as a production fault is detected. 
 

Low 

production 

Production 

OK 

High 

production 

Содержание Limpido EZ DUO 60

Страница 1: ...Installation 4 Start up 6 Calibration 7 Operation 8 Maintenance 11 Reference Version Date MPET0219 v1 0 19 02 2014 Technical Manual v1 0 Warning Carefully read this manual before installing starting o...

Страница 2: ...dissolves immediately in the water producing hydrochlorous acid HClO This powerful disinfectant destroys bacteria and algae before it retransforms into salt The amount of chlorine needed to disinfect...

Страница 3: ...in the pH of the water between 7 0 and 7 6 For information the table to the right allows determining the required production time versus the basin volume the pH for a water temperature of 25 C Since t...

Страница 4: ...he detector must be pointing in the direction of the water s flow COVER CONTACT This input must be connected to the drycontact of the cover s travel limit switch or the pool s flap Thecontact must be...

Страница 5: ...reasons the Limpido EZ Duo box must be installed more than 3 50 m from the pool edge The box must be placed on a flat stable support It must be supplied with a single phase 230V 50Hz power supply and...

Страница 6: ...chlorine from the degradation that the sun s ultraviolet UV radiation subjects it to On the other hand this cyanuric acid is not consumed and inexorably accumulates in pools treated with chlorine pebb...

Страница 7: ...he central indicator light green turns on Turn to the minus sign if the left indicator light red is lit Turn to the plus sign if the right indicator light red is lit When the central indicator light g...

Страница 8: ...CHOICE In Automatic mode pressing and holding down the key for 3 seconds allows changing the adapted thermoregulation curve The indicator light corresponding to the active curve flashes To select the...

Страница 9: ...dic flash Water temperature too low to produce 10 C 5 periodic flashes Filtration insufficient Forced filtration Permanently flashing Temperature measurement error POLARITY INDICATOR The cell is clean...

Страница 10: ...if Limpido EZ Duo could not produce throughout the required time despite forced operation the device signals underproduction by flashing the indicator light In this case the daily filtration time shou...

Страница 11: ...to keep the cell from operating in a water with too low a salt content 2g l In case a tarpaulin or a cover is used the chlorine is protected from UV radiation To prevent an over chlorination the prod...

Страница 12: ...laration The Bleu Electrique SAS Company FR 47 403 521 693 declares that the LIMPIDO EZ Duo product satisfies the safety and electromagnetic compatibility requirements of the European directives 2006...

Отзывы: