LOW TEMPERATURE AND TEMPERATURE FAULT
In the
Automatic mode
(thermoregulated), the device stops producing when the
temperature is less than 10°C. The thermoregulated indicator light intermittently turns on
(1 periodic flash).
When the temperature rises above 11°C,
Limpido EZ
®
Duo
automatically resumes the
treatment.
In case the device detects a temperature measurement fault,
Limpido EZ
®
Duo
switches to the
Permanent mode (Shock)
.
When the daily filtration duration is insufficient to allow producing the necessary time (
Automatic
mode),
Limpido EZ
®
Duo
actuates a contact to force the running of the filtration pump (cf § Forced
filtration) and indicates its state by 5 periodic flashes of the
thermoregulated
indicator light.
Thermoregulation
indicator light
Description of the state
Unlit
Shock mode
Lit
Thermoregulated automatic mode
1 periodic flash
Water temperature too low to produce (<10°C)
5 periodic flashes
Filtration insufficient / Forced filtration
Permanently flashing
Temperature measurement error
POLARITY INDICATOR
The cell is cleaned by a periodic polarity reversal.
Two indicator lights indicate the production polarity. To preserve the service life of the
cell’s electrodes, a pause of several minutes separates the changing of polarity. During
this pause, both polarity indicator lights alternately flash.
PRODUCTION INDICATOR
The production indicator allows checking the production level.
The production level is given by green and yellow indicator lights.
If no green indicator light is lit despite a production set to the
maximum, then it is necessary to check the salt ratio.
If the yellow Low production indicator light and at least one of the
three green indicator lights are lit, it means that the production
level is optimum.
Limpido EZ
®
Duo
is equipped with a protection device which
stops production as soon as a production fault is detected.
Low
production
Production
OK
High
production