This contact must be connected to the
″
Forced Operation
″
terminal strip of the filtration electrical box
(Terminal A-B of the CCEI electrical boxes) or to the filtration clock’s contact.
ELECTROLYSIS SERVOING CONTACT
Limpido EZ
®
Duo
may be connected to a programmer or a regulator to control production.
In particular, it may be connected to a Redox (ORP) or Chlorine measuring device. The measuring
device must close the dry contact (totally potential free) when the Redox potential or the chlorine
ratio is less than the desired value.
Limpido EZ
®
Duo
is particularly adapted to operating with
OXEO SP
. Refer to this device’s manual
for details on how to connect to
Limpido EZ
®
Duo
.
In this type of operation, it is recommended to use the
Shock/Permanent mode.
ELECTRICAL CONNECTION
For safety reasons, the
Limpido EZ
®
Duo
box must be installed more than 3.50 m from the pool
edge.
The box must be placed on a flat, stable support. It must be supplied with a single-phase 230V 50Hz
power supply and be protected by a 30mA differential circuit breaker in accordance with the
applicable standards.
Limpido EZ
®
Duo
is equipped with a flow detector and
must not be servoed to filtration
.
The electrolysis cell is connected directly to the box via the specific connector installed at the end of
its cord.
All the other connections are made in the connecting box as shown below.
WARNING : it is strongly recommended to have a qualified professional make the
electrical connection.
Flow
detector
Cover contact
To LIMPIDO EZ Duo
Electrolysis servoing
Filtration
Start/Stop
To Filtration
box
(1)
To travel limit
switch of the
automatic
cover
(1)
To Regulator
(OxeO SP/XP,…)
(1)
To flow detector
(supplied)
(1)
Optional connection
Jumper to remove to
connect to an
external regulator
externe
230V power supply
permanent and protected
L
N