background image

CCEI 

Limpido EZ

®

  

Duo

 

v1.0 

 

Page 2 

TECHNICAL DATA 

General 

 

Electrolysis 

EZ Duo 60 

EZ Duo 100 

pH regulation 

 

Dimensions (lxhxd) 

260x180x80 

Chlorine production 

16g/h 

24g/h 

Measurement range 

3 to 10 

Weight 

6kg 

Basin volume 

20 to 60m

3

 

30 to 100m

3

 

Precision 

0.2 

Power supply 

230V/50Hz 

Cell cleaning 

Polarity reversal 

Setpoint range 

7.0 to 7.6 

Consumed power 

150W 

Salt ratio 

2.5 to 5 g/l 

Pump type 

peristaltic 

Degree of protection 

IP-65 

Max pressure  

3 bar 

Max flow rate 

1.8l/h 

Isolation 

Class II 

Max flow rate 

22 m

3

/h 

Regulation mode 

pH- 

 

Delivered accessories 

 

Electrolysis cell with 50 mm dia. unions 

pH probe + pH 7 standard solution 

Flow rate detector 

½’’ dia. pH injection nozzle & probe holder  

50mm/¾’’ dia. clamp 

2 x 50mm /½’’ dia. clamps  

Technical manual 
Fastening screws and pins 
Mini adjusting screwdriver 

¾’’ dia. nipple 

Crystal tube (4m)+ suction strainer 

 

OVERVIEW 

Limpido  EZ  Duo

  is  an  automatic  swimming  pool  water  treatment  system.  It  is  based  on  two 

principles :  sterilisation  by  electrolysis  of  the  salty  water  and  regulation  of  the  pH.  Both  of  these 
principles combine to maintaining a pool’s water healthy and limpid. 
 

ELECTROLYSIS OF SALT 

Electrolysis  separates  the  salt  (NaCl)  of  salty  water  into  sodium  (Na)  and  Chlorine  (Cl).  Chlorine 
dissolves  immediately  in  the  water  producing  hydrochlorous  acid  (HClO).  This  powerful  disinfectant 
destroys bacteria and algae before it retransforms into salt. 
The  amount  of  chlorine  needed  to  disinfect  a  pool  increases  with  the  temperature  and  the  pH 
(alkalinity) of the water.  
 
The  production  of  chlorine  must  be  adjusted  acccording  to  the  environment  and  the  water’s 
characteristics : 

 

the water’s conductivity 

 

the water’s temperature 

 

the volume of the basin to be treated 

 

the water’s pH 

 
For the installation’s safety, the electrolyser produces chlorine only when the flow detector signals the 
circulation of water in the cell.  
Thus, the electrolyser produces chlorine only during the filtration ranges determined by the swimming 
pool’s electrical box’s programming clock. Inside these filtration ranges, the production time is made 
up of cycles of two periods (Normal and Reverse) which alternate the polarity of the electrodes. This 
reversal of polarity prevents the scaling of the electrodes.  
 

 
Thus, a production cycle is broken down into 4 phases :  

Phase 1, normal production. 
Phase 2, rest. 
Phase 3, production in reverse mode. 
Phase 4, rest. 

 
When a filtration range terminates, 

Limpido EZ Duo

 stops producing and when the filtration restarts, 

it resumes its cycle exactly at the point where it was interrupted. 

wait 

Prod 

Production - 

Prod 

Production - 

wait 

Production cycle = 200 min. 

Phase 1 

Phase 2 

Phase 3 

Phase 4 

Содержание Limpido EZ DUO 60

Страница 1: ...Installation 4 Start up 6 Calibration 7 Operation 8 Maintenance 11 Reference Version Date MPET0219 v1 0 19 02 2014 Technical Manual v1 0 Warning Carefully read this manual before installing starting o...

Страница 2: ...dissolves immediately in the water producing hydrochlorous acid HClO This powerful disinfectant destroys bacteria and algae before it retransforms into salt The amount of chlorine needed to disinfect...

Страница 3: ...in the pH of the water between 7 0 and 7 6 For information the table to the right allows determining the required production time versus the basin volume the pH for a water temperature of 25 C Since t...

Страница 4: ...he detector must be pointing in the direction of the water s flow COVER CONTACT This input must be connected to the drycontact of the cover s travel limit switch or the pool s flap Thecontact must be...

Страница 5: ...reasons the Limpido EZ Duo box must be installed more than 3 50 m from the pool edge The box must be placed on a flat stable support It must be supplied with a single phase 230V 50Hz power supply and...

Страница 6: ...chlorine from the degradation that the sun s ultraviolet UV radiation subjects it to On the other hand this cyanuric acid is not consumed and inexorably accumulates in pools treated with chlorine pebb...

Страница 7: ...he central indicator light green turns on Turn to the minus sign if the left indicator light red is lit Turn to the plus sign if the right indicator light red is lit When the central indicator light g...

Страница 8: ...CHOICE In Automatic mode pressing and holding down the key for 3 seconds allows changing the adapted thermoregulation curve The indicator light corresponding to the active curve flashes To select the...

Страница 9: ...dic flash Water temperature too low to produce 10 C 5 periodic flashes Filtration insufficient Forced filtration Permanently flashing Temperature measurement error POLARITY INDICATOR The cell is clean...

Страница 10: ...if Limpido EZ Duo could not produce throughout the required time despite forced operation the device signals underproduction by flashing the indicator light In this case the daily filtration time shou...

Страница 11: ...to keep the cell from operating in a water with too low a salt content 2g l In case a tarpaulin or a cover is used the chlorine is protected from UV radiation To prevent an over chlorination the prod...

Страница 12: ...laration The Bleu Electrique SAS Company FR 47 403 521 693 declares that the LIMPIDO EZ Duo product satisfies the safety and electromagnetic compatibility requirements of the European directives 2006...

Отзывы: